N°REG.
Register
15
MinRPM
16
VacMIN
17
IN1 Range
18
IN2 Range
19
IN1 Set
20
IN1 Banda
21
IN2 Set
22
IN2 Banda
23
InD
24
setMODBUS
25
IDIOMA
26
SP-2 PRESION
27
SP-2 CAUDAL
28
SP Temp
29
adMODBUS
30
ALARMA
31
FECHA
0x0000
32
HORA
0x0000
33
LUNES T1
0x0000
34
LUNES T2
0x0000
35
LUNES T3
0x0000
36
MARTES T1
0x0000
37
MARTES T2
0x0000
38
MARTES T3
0x0000
39
MIERCOLES T1
0x0000
40
MIERCOLES T2
0x0000
41
MIERCOLES T3
0x0000
42
JUEVES T1
0x0000
43
JUEVES T2
0x0000
44
JUEVES T3
0x0000
45
VIERNES T1
0x0000
46
VIERNES T2
0x0000
Min.
Max.
Description
100
500
Increases de 100
80
150
Increases de 10
0
100
%HR incrementos
0
50
°C incrementos
0
2000
PPM incrementos
0
100
%HR Increases
0
50
°C Increases
0
2000
PPM Increases
0
IN1 Range
Increases de 1
0
IN1 Range
Increases de 1
0
IN2 Range
Increases de 1
0
IN2 Range
Increases de 1
0
1
1
PIRange
Increases de 50
0=ENGLISH
1=SPANISH
0
3
2=FRENCH
3=GERMAN
25
100
Increases de 1
50
100
Increases de 1
-10
50
Increases de 1
1
247
Increases de 1
0
100
0
1
0xfe7f
Day/Month/Year
0x3dfb
Hour/Minute
0x063b
Hour/Minute
0x063b
Hour/Minute
0x063b
Hour/Minute
0x063b
Hour/Minute
0x063b
Hour/Minute
0x063b
Hour/Minute
0x063b
Hour/Minute
0x063b
Hour/Minute
0x063b
Hour/Minute
0x063b
Hour/Minute
0x063b
Hour/Minute
0x063b
Hour/Minute
0x063b
Hour/Minute
0x063b
Hour/Minute
Default
300
80
100
2000
70
40
1000
1000
0=NO
0
1=NC
100
(CAB-125 ECOWATT)
150
(CAB-150/160/200/150/315
ECOWATT)
200
(CAB-355/400 ECOWATT)
0
25
50
1
0x088E
0x0000
0x0200
0x0300
0x0480
0x0200
0x0300
0x0480
0x0200
0x0300
0x0480
0x0200
0x0300
0x0480
0x0200
0x0300
64
Comments
Min RPM alarm
Minimum voltage AC
motor
Background scale in
proportional mode input 1
Background scale in
proportional mode input 2
Set point proportional
mode input 1
Margin (+/-) centered in
IN1 Set
Set point proportional
mode input 2
Margin (+/-) centered
in IN2 Set
Digital input inverter
MODBUS set point
Language
Night set point in PI
PRESSURE mode
Night set point in PI
VOLUME mode
Temperature set point
(only for CTBH ECOWATT
models)
Current date
Current date
Starting period 1 Monday
Starting period 2 Monday
Starting period 3 Monday
Starting period 1 Tuesday
Starting period 2 Tuesday
Starting period 3 Tuesday
Starting period 1
Wednesday
Starting period 2
Wednesday
Starting period 3
Wednesday
Starting period 1 Thursday
Starting period 2 Thursday
Starting period 3 Thursday
Starting period 1 Friday
Starting period 2 Friday