    Installation Manual
    AIR-TO-WATER HYDROMODULE + TANK
    ADC0916*E8*
    Required tools for Installation Works
    1 Philips screw driver
    2 Level gauge
    3 Electric drill
    4 Spanner
    SAFETY PRECAUTIONS
    Read the following "SAFETY PRECAUTIONS" carefully before installation of Air-To-Water Hydromodule + Tank (here after referred to as "Tank Unit").
    Electrical works and water installation works must be done by licensed electrician and licensed water system installer respectively. Be sure to use the correct
    rating and main circuit for the model to be installed.
    The caution items stated here must be followed because these important contents are related to safety. The meaning of each indication used is as below.
    Incorrect installation due to ignorance or negligence of the instructions will cause harm or damage, and the seriousness is classifi ed by the following indications.
    Please leave this installation manual with the unit after installation.
    WARNING
    This indication shows the possibility of causing death or serious injury.
    CAUTION
    This indication shows the possibility of causing injury or damage to properties only.
    The items to be followed are classifi ed by the symbols:
    Symbol with white background denotes item that is PROHIBITED from doing.
    Symbol with dark background denotes item that must be carried out.
    Carry out test run to confi rm that no abnormality occurs after the installation. Then, explain to user the operation, care and maintenance as stated in
    instructions. Please remind the customer to keep the operating instructions for future reference.
    If there is any doubt about the installation procedure or operation, always contact the authorized dealer for advice and information.
    Do not use unspecifi ed cord, modifi ed cord, joint cord or extension cord for power supply cord. Do not share the single outlet with other electrical appliances. Poor
    contact, poor insulation or over current will cause electrical shock or fi re.
    Do not tie up the power supply cord into a bundle by band. Abnormal temperature rise on power supply cord may happen.
    Keep plastic bag (packaging material) away from small children, it may cling to nose and mouth and prevent breathing.
    Do not use pipe wrench to install refrigerant piping. It might deform the piping and cause the unit to malfunction.
    Do not purchase unauthorized electrical parts for installation, service, maintenance and etc.. They might cause electrical shock or fi re.
    Do not add or replace refrigerant other than specifi ed type. It may cause product damage, burst and injury etc.
    Do not use the hot water produced by the Tank Unit for drinking or food preparation. It may cause illness to the user.
    Do not place containers with liquids on top of the Tank Unit. It may cause Tank Unit damage and/or fi re could occurs if they leak or spill onto the Tank Unit.
    For electrical work, follow local wiring standard, regulation and this installation instruction. An independent circuit and single outlet must be used. If electrical
    circuit capacity is not enough or defect found in electrical work, it will cause electrical shock or fi re.
    For water circuit installation work, follow to relevant European and national regulations (including EN61770) and local plumbing and building regulation codes.
    Engage dealer or specialist for installation. If installation done by the user is defective, it will cause water leakage, electrical shock or fi re.
    This is a R410A model, when connecting the piping, do not use any existing (R22) pipes and fl are nuts. Using such same may cause abnormally high pressure
    in the refrigeration cycle (piping), and possibly result in explosion and injury. Use only R410A refrigerant.
    Thickness or copper pipes used with R410A must be 0.8 mm or more. Never use copper pipes thinner than 0.8 mm.
    It is desirable that the amount of residual oil is less than 40 mg/10 m.
    When install or relocate Tank Unit, do not let any substance other than the specifi ed refrigerant, eg. air etc mix into refrigerant cycle (piping). Mixing of air etc. will
    cause abnormal high pressure in refrigeration cycle and result in explosion, injury etc.
    Install according to this installation instructions strictly. If installation is defective, it will cause water leakage, electrical shock or fi re.
    F616665
    5 Knife
    6 Measuring tape
    8 Multimeter
    WARNING
    9 Torque wrench
    58.8 N•m (5.8 kgf•m)
    ENGLISH ................ 1
    ESPAÑOL ............... 9
    ITALIANO .............. 17
    NEDERLANDS ..... 25
    PORTUGUÊS ....... 33
    ............. 41
    ČESKY .................... 49
    FRANÇAIS ........... 57
    DEUTSCH ............ 65
    SVENSKA ............. 73
    NORSK ................. 81
    SUOMI .................. 89
    DANSK ................. 97
    1
    Tabla de contenido
    loading

    Resumen de contenidos para Panasonic ADC0916E8 Serie

    • Página 9: M (4.2 Kgf•M)

      Manual de instalación HIDROMÓDULO AIRE A AGUA + ACUMULADOR ADC0916*E8* Herramientas Necesarias para Trabajos de Instalación 1 Destornillador de Estrella 5 Cuchillo 9 Llave Dinamométrica 117,6 N•m (11,8 kgf•m) 42 N•m (4,2 kgf•m) 2 Indicador de Nivel 6 Cinta métrica 58,8 N•m (5,8 kgf•m) 3 Taladro Eléctrico 7 Megóhmetro...
    • Página 10 Instale sobre un punto fi rme y sólido el cual pueda sostener el peso del aparato. Si la fi rmeza no es la sufi ciente o la instalación es inadecuada, el aparato se caerá y causará lesiones. No utilice empalmes para el cable de conexión de acumulador ACS/ unidad exterior. Utilice el cable de conexión del acumulador ACS / unidad exterior CONECTE EL CABLE AL ACUMULADOR y conéctelo con fi...
    • Página 11 Accesorios adjuntos Accesorios de no incluido N°. Pieza Cant. Modelo Especifi caciones Fabricante N°. Parte accesoria Cant. N°. Parte accesoria Cant. Actuador electromotórico SFA21/18 AC230V Siemens Cuerpo Válvula Pies ajustables Embalaje 2 vías Válvula 2 vías VVI46/25 Siemens Tipo Analógico RAA20 Termostato AC230V...
    • Página 12 El acumulador ACS está diseñado para la combinación con la unidad exterior Exterior Interior de bomba de calor de aire a agua Panasonic. Si se utiliza una unidad exterior 15 mm de otro fabricante en combinación con el acumulador ACS Panasonic, no se garantiza el funcionamiento óptimo y la fi...
    • Página 13 • (C) Tubería de válvula de seguridad de drenaje No utilice tuberías gastadas. • • No aplique fuerza excesiva sobre los tubos que pueda dañarlos. Conecte una manguera de drenaje con Conector de • Elija el sellador adecuado que pueda soportar las presiones y temperaturas un diámetro interior de 15 mm de la manguera del sistema.
    • Página 14 • Asegúrese de que el color de los cables de la unidad exterior y el número terminal sean los mismos que los del acumulador ACS respectivamente. • El cable de conexión a tierra será más largo que otros cables, según se muestra en la fi gura de seguridad eléctrica en el caso de que se deslice fuera del soporte del cable.
    • Página 15 • Si no oye ningún ruido (del drenaje de agua), contacte a su proveedor CARGAR Y DESCARGAR EL AGUA local autorizado. • Baje la palanca después de terminar la comprobación. • En el caso en que el agua se drene desde el acumulador ACS, apague •...
    • Página 16 AJUSTE EL CAUDAL DE AGUA CON LA BOMBA CIRCULADORA 2 Mantenimiento para barra de ánodo Para proteger el cuerpo del acumulador ACS hay colocada una barra de ánodo Antes de ajustar el caudal de agua, asegúrese de que el volumen total de dentro del acumulador ACS.

    Tabla de contenido