NOTE:
The engine may be damaged if the choke lever is moved further beyond
●
the "CLOSE" position.
If the engine fires and stops, return this lever to the "OPEN" position and
●
pull the starter handle several times to start the engine again.
If the operator keeps pulling the starter handle several times with the
●
choke lever left in the "CLOSE" position, the engine may be difficult to
start because of flooding of the fuel.
In case of flooding of the fuel, remove the spark plug and pull the handle
●
several times rapidly to discharge any excess fuel. Dry the spark plug
electrode.
When the throttle valve (1) does not return to a position in contact with
●
the idling adjusting screw (2) even if the throttle lever is set to the low
speed, correct the control cable (3) catching state to ensure proper
return of the valve.
2) When the engine is warm (warm start)
(1) Put the engine on a flat surface.
(2) Push the primer pump several times.
(3) Make sure that the choke lever is open.
(4) Stump the pedal with your right foot, and hold the top of the unit
with left hand to prevent the engine from moving.
(5) Pull slowly the starter handle till feeling compression. Then pull
it strongly.
(6) When the engine is difficult to start, open the throttle valve by
about 1/3.
2. Stopping
For tube throttle model
Release the throttle trigger (2) and then set the stop control lever (1) to
"O" position.
For hip throttle model
Set the throttle lever (1) to the low speed position to reduce the engine
speed. Then set the stop switch (2) to "O" position.