• Select blinking LED L6.
• Press the SET key twice consecutively in a time period of 2 seconds.
• The LED will switch off and the operation will be completed.
During programming, instead of the SET key on the control unit you can use
the button on the remote, providing the remote has been saved beforehand.
8.1.6. LED L6 - LEAVES DELAY:
The control unit is factory set with 4 Sec. leaves opening and closing delay.
Proceed as follows if you wish to modify that period:
• By the key SELECT, position yourself on the blinking LED L6;
• Press the SET key;
• Wait for a time equivalent to the desired time interval for leaves delay in
the closing phase (from 4 sec. up to 15 min.);
• Press the SET button again for an instant, thus determining the door
delay time to be memorised (during opening it is fixed at 4 seconds,
whereas it will be the gate delay closing time for the programmed time);
• LED L6 becomes steady on and programming will be completed: the
delay time is fixed for opening leaves at 4 sec and it is up to 15 sec for
closing leaves
If you want to deactivate this function (without leaves delay),
• Select blinking LED L6
• Press the SET key twice consecutively in a time interval of 2 seconds,
at the same time the LED will switch off and the operation will be
terminated.
8.1.7. LED L7 - AUTOMATIC PROGRAMMING:
The control unit allows to carry out a Self-learning Programming (SIMPLIFIED)
to automatically regulate stroke and slowdowns of the gate. To set a
new stroke, programming must be carried out with leaves in intermediate
position (partially open) as follows:
• Place the doors in a half-open position
• Make sure that the setting of the "SPEED" trimmer allows the motors to
reach the limit switch (if there is no encoder and / or limit switches);
• By the key SELECT, position yourself on the blinking LED no.7;
• Press the SET key;
• To determine its zero position, Motor no.2 performs its closure until it
reaches the limit switch or mechanical stop;
• Afterwards the same operation will be repeated by the Motor no. 1;
• The control unit executes the Auto programming procedure by
performing a complete opening and closing cycle and the Deceleration
cycle is set automatically too at approximately 15% of the complete
cycle;
• Press the SET button to memorize the motor stroke.
During Automatic Programming, instead of the SET key on the control unit
you can use the button on the remote, providing the remote has been
saved beforehand.
Important notes:
- In the event that the motors move in a manner other than that described:
• During the initial phase of memorising the door stroke, release the SET
button and stop programming;
• Disconnect the power supply to the control unit (mains and any battery);
• Change the position of Dip Switch SW2 to change the drive direction to
the desired motor without physically using the electrical connections.
- During Automatic Programming, the radio control button (if previously
memorised) may be used instead of the control unit SET button.
- It is not possible to carry out Automatic Programming in the absence of
limit switches and/or encoders wired to the control unit.
8.2 EXTENDED MENU 1
The control unit is factory set to allow direct selection exclusively of the main
menu functions. If you wish to enable the functions described in Extended
Menu 1, proceed as follows:
• Select blinking LEV LED and press SET once;
• Press SET once
• The LED will start blinking (alternate flashing of LEV LED
);
In this way you have access to the setting of the following functions:
L1
HOLD-TO-RUN
ON
L2
PEDESTRIAN BUTTON /
SINGLE LEAF
SINGLE DOOR
PP/OPEN
PPED/CLOSE
L3
PEDESTRIAN BUTTON / DS3
DS3
L4
PHOTOTEST
ON
L5
DS2 STOP IN CLOSE
ON
L6
DS1 PARTIAL INVERSION
ON
L7
BLOCK / 8K2
ON
LEV
MENU
There will be 30 seconds to select the functions of the Extended Menu
1 using the SELECT and SET keys; once an additional 30 seconds have
elapsed the control unit reverts to the main menu.
8.2.1. LED L1 - HOLD-TO-RUN:
The control unit provides the opportunity to set the "Hold-to-run" function.
With this function enabled using either the remotes or the Pushbuttons
to operate the gate, the following operation will be obtained: the
command must be kept maintained constantly to move the gate.
When the command is released, the movement will stop immediately.
Proceed as follows if you wish to enable the function:
• Make sure you have enabled the extended Menu 1 (as shown by the
alternate flashing 1 0 1 0 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L1;
• Press the SET key;
• LED L1 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the previous configuration.
8.2.2. LED L2 - SINGLE LEAF OR PP. BUTTON = OPEN, PED. BUTTON
= CLOSE:
The control unit allows a N.O. Pushbutton to be connected (CN2 input no.
10) to activate the gate in Pedestrian Opening mode.
It is however possible to use this input to connect a N.O. pushbutton
operating in a different manner.
If you wish to enable the "Single Leaf" function, proceed as follows:
• The LED will start blinking (alternate flashing 1 0 1 0 1 0 of LEV LED);
• Select blinking LEV LED and press SET once;
• Press the SET key;
• By the key SELECT, position yourself on the blinking LED L2;
With this function enabled, the Pushbutton can be used to activate
exclusively Operator 1.
In contrast, if you wish to enable "OPEN-CLOSE" mode in order to
use the Pedestrian Pushbutton to activate exclusively closing of the gate
and the P/P Pushbutton to (CN2 input no. 11) to activate exclusively
opening of the gate, repeat the operation described above, pressing
the SELECT key twice (LED L2 will blink rapidly) instead of just once.
Repeat the procedure if you wish to restore the initial configuration.
8.2.3. LED L3 - PEDESTRIAN PUSHBUTTON / DS3:
The control unit allows a N.O. Pushbutton to be connected (CN2 input no.
10) to activate the gate in Pedestrian Opening mode.
However, this input can be used to connect a DS3 photocell:
• Select blinking LEV LED and press SET once; The LED will start blinking
(alternate flashing 1 0 1 0 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L3;
• Press the SET key;
COMUNELLO ®Copyright 2019 - All rights reserved
OFF
PEDESTRIAN BUTTON
PEDESTRIAN BUTTON
OFF
OFF
OFF
OFF
1 FLASH
39