Before Startup
Check oil level
Read the oil level display when the
device is not running. The oil level
must be above the two pointers.
Activate deaeration of oil container
Unscrew the fastening screws of
the device hood; remove the device
hood.
Cut off tip of oil container cover
Fasten the device hood.
Attaching the Accessories
Note: The EASY!Lock system joins
components with a quick-fasten thread
solidly and securely with just one turn.
1.
Mount the nozzle on the spray
lance (marking on the adjustment
ring at the top) and hand-tighten it
(EASY!Lock).
Join the spray lance with the trigger
gun and tighten until hand-tight
(EASY!Lock).
Loosen the clamps of the pushing
handle.
Adjust the handle to the desired
height.
Tighten the clamps of the pushing
handle.
Join the high-pressure hose with
trigger gun and high-pressure con-
nection of the appliance and tighten
until hand-tight (EASY!Lock).
8
2.
EN
Start up
WARNING
Risk of injury! Appliance, accessories,
supply lines and connections must be
in fault-free condition. If they are not in
a perfect state then the appliance must
not be used.
Electrical connection
DANGER
Danger of injury by electric shock.
It is imperative to connect the appli-
–
ance to the electric mains by means
of a plug. It is forbidden to perma-
nently connect the appliance to the
power supply. The plug serves for
the disconnection from the mains.
The plug and coupling of the exten-
–
sion cable used must be watertight.
Use the extension cord that has an
–
adequate cross-section (see "Tech-
nical Data") and unwind it fully from
the cable drum.
For connection values, see type plate/
technical data.
GFCI INSTRUCTIONS
STEP 1: Plug the Ground Fault Cir-
–
cuit Interrupter (GFCI) into a work-
ing outlet.
STEP 2: Press ''TEST'', then press
–
''RESET'' to assure proper connec-
tion to power.
Note: The actual appearance of the
GFCI may be different from this illus-
tration.
– 6