INSTALLATION
For easy installation, select an existing light with a wall
switch for replacement.
For best performance, locate the fixture about 8 ft. (2.4 m)
above the ground.
CAUTION: The sensor must be mounted below the
lamp housing for wall installations.
❒ Drill out the holes if needed
to mount the backplate to the
junction box.
CAUTION to avoid fire or burn hazards:
• Allow fixture to cool before touching. The bulb
and fixture operate at high temperatures.
• Keep fixture at least 2" (5 cm) from combustible
materials. Do not aim at objects closer than 3 feet
(1 m).
• Re-lamp with type T 150W (or less) halogen 120
VAC lamp only.
For under eave installation, the sensor head must
be rotated as shown in the next two steps for proper
operation and to avoid the risk of electrical shock.
Rotate the sensor head to-
wards the clamp screw joint.
Then rotate the sensor
head counterclockwise
180° so the controls face
down.
B
I
ULB
NSTALLATION AND
❒ When relamping, turn power off and let the fixture
cool.
❒ Remove the screw that holds the glass cover shut.
Remove the old bulb by pushing the bulb towards
the right until the left side of the bulb is clear of the
left socket.
❒ Turn the power to the lighting circuit off at the
❒ Remove the existing light fixture.
❒ Strip about 5/8" insulation from the existing junction
❒ Route the Light Control's wires through the large
❒ Twist the junction box wires and fixture wires together
❒ Align the Light Control cover plate and cover plate
❒ If not installed on a weatherproof box or if an adaptor
R
.
ELAMPING
2
fuse or circuit breaker box.
box wiring.
hole in the gasket.
as shown. Secure with wire connectors.
Black to Black
M
L
OUNT THE
gasket and the junction box. Insert and tighten the
mounting screws.
plate is used, caulk the wall plate and mounting
surface with silicone weather sealant.
RIGHT
The halogen light must be
mounted horizontally (+/- 4°).
White to White
Cover Plate
Gasket
C
.
IGHT
ONTROL
WRONG
595-5574-05