Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight
hours.
• LED indicates motion was sensed (day or
night).
Requirements
• The light control requires 120-volts AC.
• If you want to use Manual Mode, the control must
be wired through a switch.
• Some codes require installation by a qualifi ed
electrician.
OPERATION
Mode:
On-Time:
Test
5 Sec
Normal 1, 5, 10 min.
Manual
Until Dawn*
* resets to Auto Mode at dawn.
Note: When fi rst turned on wait about 1
for the circuitry to calibrate.
© 2007 HeathCo LLC
Works:
Day
Night
x
x
x
x
1
/
minutes
2
Put the ON-TIME switch on the
bottom of the sensor in the TEST
position.
Put the ON-TIME switch in the 1,
5, or 10 minute position.
MANUAL MODE
Manual mode only works at night
because daylight returns the sen-
sor to AUTO.
Flip the light switch off for one
second then back on to toggle
between AUTO and MANUAL
MODE.
Manual mode works only with
the ON-TIME switch in the 1, 5,
or 10 position.
Mode Switching Summary
TEST
AUTO
MANUAL MODE
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the
1
calibration time (1
/
2
AUTO mode.
TEST
ON-TIME
10 5 1 TEST
AUTO
ON-TIME
10 5 1 TEST
1 Second OFF
then...
... back on.
Move ON-TIME Switch
to 1, 5, or 10 minutes
Flip switch off for
one second then
back on*
min.) the control will be in the
598-1155-01
Tabla de contenido
loading

Resumen de contenidos para Heath Zenith Secure Home SH-5407

  • Página 1 TEST ON-TIME Put the ON-TIME switch on the bottom of the sensor in the TEST position. Replacement 10 5 1 TEST AUTO Motion Sensor ON-TIME Put the ON-TIME switch in the 1, Model SH-5407 5, or 10 minute position. 10 5 1 TEST Features •...
  • Página 2 ❒ After screwing the sensor into the wall plate, INSTALLATION connect the junction box wires to the light control For under eave installation, the sensor head wires by twisting together and securing with wire must be rotated as shown in the next two steps connectors.
  • Página 3 ❒ Turn the RANGE control to the mid position and ❒ Loosen the clamp screw Clamp the ON-TIME control to the TEST position. in the sensor ball joint and Screw gently rotate the sensor. ❒ Walk through the cover- Ball RANGE ON-TIME age area noting where...
  • Página 4: Troubleshooting Guide

    TROUBLESHOOTING GUIDE SYMPTOM POSSIBLE CAUSE SYMPTOM POSSIBLE CAUSE Lights will not 1. Light switch is turned off. Lights stay on 1. A lamp is positioned too close to the sensor come on. 2. Light is loose or burned out. continuously. or pointed at nearby objects that cause heat 3.
  • Página 5: Repuesto Universal Para El Cabezal Del Detector

    Cuando lo prenda por primera vez espere unos 1 minutos hasta que el circuito se calibre. Para PRUEBA: ON-TIME Ponga el interruptor de tiempo (ON- Repuesto Universal TIME), al fondo del detector, en la posición de prueba (TEST). Para el Cabezal 10 5 1 TEST del Detector Para AUTOMATICO:...
  • Página 6: Instalacion

    ❒ Quite el aparato existente de luz, si existe. INSTALACION ❒ Después de atornillar el detector en la placa Para instalarlo bajo el alero, la cabeza del de la pared, conecte los alambres de la caja detector debe ser girada como se muestra en de empalme a los alambres del control de luz los dos pasos siguientes para evitar el riesgo de torciéndolos juntos y uniéndolos con conectores...
  • Página 7: Especificaciones

    o hacia los lados para Tornillo ON-TIME RANGE cambiar el área de pro- Sujetador tección. Mantenga al ON-TIME RANGE detector por lo menos Unión 10 5 1 TEST a 1 pulgada (2.5 cm) de Esférica 10 5 1 TEST MINUTES las lámparas.
  • Página 8: Guia De Investigacion De Averias

    GUIA DE INVESTIGACION DE AVERIAS POSIBLE CAUSA SINTOMA POSIBLE CAUSA SINTOMA La luz no se enci- 1. El interruptor de luz está apagado. La luz se 1. Un faro está colocado demasiado cerca al detector o apunta a objetos cercanos que ende.

Tabla de contenido