Heath Zenith SL-5211 Manual Del Usuario
Heath Zenith SL-5211 Manual Del Usuario

Heath Zenith SL-5211 Manual Del Usuario

Control de luz decorativo sensor de movimiento
Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

Instant Motion Sensor
Light Control
Model SL-5211
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
Requirements
• The Light Control requires 120-volts AC.
• If you want to use Manual Override, the control must be
wired through a switch.
• Some codes require installation by a qualified elec-
trician.
The SL-5211 package includes:
• The Sensor and Lamp Module
• Two mounting screws
Typical Installation
The lamp module is not weather tight. It should only be
used inside of a light fixture.
Existing Light
Fixture
Sensor
Module
Sensor
Cord
© 2007 HeathCo LLC
Features
Parts
Lamp
Module
OPERATION
Mode:
On-Time:
Test
5 Sec
Auto
1, 5 or 10 min
Manual
Until Dawn*
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1
circuitry to calibrate.
Put the ON-TIME switch on the bottom of
the sensor in the TEST position.
Put the ON-TIME switch in the 1, 5, or 10
minute position.
MANUAL MODE
Manual mode only works at night be-
cause daylight returns the sensor to
AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the ON-
TIME switch in the 1, 5, or 10 position.
Mode Switching Summary
TEST
AUTO
MANUAL MODE
* If you get confused while switching modes, turn the power
off for one minute, then back on. After the calibration time
the control will be in the AUTO mode.
Works:
Day
x
1
/
minutes for the
2
TEST
ON-TIME
10 5 1 TEST
AUTO
ON-TIME
10 5 1 TEST
1 Second OFF
then...
... back on.
Move ON-TIME Switch to
1, 5, or 10 minutes
Flip light switch off
for one second then
back on*
595-4238-07
Night
x
x
x
Tabla de contenido
loading

Resumen de contenidos para Heath Zenith SL-5211

  • Página 1 10 5 1 TEST trician. MANUAL MODE Parts Manual mode only works at night be- The SL-5211 package includes: cause daylight returns the sensor to • The Sensor and Lamp Module AUTO. • Two mounting screws Flip the light switch off for one second...
  • Página 2 INSTALLATION ❒ Before proceeding with the installation, TURN OFF THE POWER TO THE LIGHTING CIRCUIT AT THE CIRCUIT BREAKER OR FUSE BOX to avoid electrical shock. There are two types of decorative fixtures that the Instant Light Control should be used with as shown here. ‘A’...
  • Página 3 ❒ Walk through the coverage area TEST AND ADJUSTMENT noting where you are when the ❒ Turn on the circuit breaker and light switch. lights turn on. Move the sensor head up, down, or sideways to NOTE: Sensor has a 1 minute warm up period before it Aim Sensor Down change the coverage area.
  • Página 4: Troubleshooting Guide

    TROUBLESHOOTING GUIDE SYMPTOM POSSIBLE CAUSE SYMPTOM POSSIBLE CAUSE Light will not come 1. Light switch is turned off. Light stays on 1. A sensor is positioned too close to the lamp or 2. Flood light is loose or burned out. continuously.
  • Página 5: Control De Luz Decorativo Sensor De Movimiento

    El modo manual funciona sólo por la Piezas noche porque la luz del día pone al detector en modo AUTOMATICO. El SL-5211 incluye: • El Módulo de Sensory Módulo de linterna lámpara 1 segundo • Dos tornillos para el módulo...
  • Página 6: Instalacion

    INSTALACION ❒ Antes de continuar con la instalación, CORTE LA ENERGIA QUE VA AL CIRCUITO DE LA LUZ DESDE EL CORTACIRCUITOS O DESDE LA CAJA DE FUSIBLES para evitar un sacudón eléctrico. Existen dos tipos de instalaciones fijas decorativas que se deben usar con el Control Ins-tantáneo de Luz, como se demuestra en la figura baja.
  • Página 7: Prueba Y Ajuste

    El detector es menos sensible del movimiento que se dirige PRUEBA Y AJUSTE hacia él. ❒ Prenda el cortacircuitos y el interruptor de luz. Movimiento NOTA: El detector tiene un período de cerca de 1 minutos Movimiento de calentamiento antes de detectar movimiento. Cuando lo prenda por primera vez, espere 1 minutos.
  • Página 8: Guia De Investigacion De Averias

    GUIA DE INVESTIGACION DE AVERIAS SINTOMA POSIBLE CAUSA SINTOMA POSIBLE CAUSA La luz no se 1. El interruptor de luz está apagado. La luz se 1. El Control de Luz puede estar instalado en un enciende. 2. El faro está flojo o fundido. prende lugar relativamente oscuro.

Tabla de contenido