INSTRUCTIONS FOR INSTALLATION Art. 611-612
The product must be installed exactly as supplied by Teuco, otherwise warranty will be invalidated.
The directions for installation must be observed to the letter, as must those concerning recommended materials and the accessories
supplied with the product.
Electrical connections must be carried out in compliance with national safety regulations, as indicated in the preinstallation data sheet.
This manual constitutes an integral part of the product and must be kept for future reference.
Data and specifications indicated are not binding on the company: Teuco Guzzini SpA reserves the right to make such changes as
are deemed appropriate without prior notice and without any obligation to update.
This product is intended for home use. In the event of a Teuco minipool being commissioned for public use, procurement managers
must ensure compliance with all statutory regulations governing safety, water treatment and utility systems normally in force in the
country of installation.
3
OPENING THE PACKING
Remove the crate and packing, leaving the minipool on the pallet.
Whatever transport and handling operations are involved, use only
the pallet on which the minipool is packed for shipment.
4
REMOVING THE COVER
Remove the cover (art. 612 only: unhook the retaining straps at the four
corners).
The cover is not intended to carry weights.
Do not sit, step or lie on the cover.
Do not place objects on the cover.
The canvas can be dangerous if not secured or properly closed.
Failure to follow the instructions for securing the canvas can result
in danger to the user.
Remove the canvas completely before stepping into the pool,
otherwise there is a risk of being trapped.
5
A
REMOVING THE SIDE PANELS
Undo the screws (Z) at the bottom of the side panels, then remove each
panel by gripping at the base and pulling upwards to release the clips
(Y) from their sockets.
5
B
REMOVING THE CORNER PANELS
Remove the corner panels of the minipool by gripping each one at the
base and pulling upwards to release the clips (Y) from their sockets.
6
A
FITTING THE LIFTING BARS
Fit the lifting bars to the corners of the frame and secure in place with
the nuts and bolts provided.
NEVER LIFT THE MINIPOOL BY THE RIM OR BY THE PIPELINES.
THE MINIPOOL MUST NEVER BE LIFTED WHEN FULL OF WATER.
6
B
PLACEMENT
When lifting and placing the minipool, use slings of suitable load
capacity at least 4 metres in length (distance from the bars on the
minipool frame to the lift hook).
Slip the slings over the bars (B) and proceed to lift the minipool, then
place it on the selected site (the weight of the minipool when empty is
approximately 350 kg).
Remove the bars (B) and keep handy for future use, if needed.
7
PLUMBING CONNECTIONS
DRAIN CONNECTION
The Teuco minipool has a gate type drain valve with a
ø 40 mm connection.
Connect the valve to the main drain by way of a trap (see preinstallation
data sheet - step 2).
FILL CONNECTION
The recommended method of filling the Teuco minipool is to use a hose
(taking care not to immerse the end as this could cause a reflux of water
back into the main).
WARNINGS
8
HEAT EXCHANGER CONNECTIONS
The minipool is provided with a switch box (M) containing a relay with a
"normally open voltage-free" contact (3A Max - spare terminals connected to
Black and White conductors) that can be used as on/off switch control for a
boiler, a recirculation pump, a zone valve or other appliance/component. The
electrical connection to the box must be permanent, able to handle the rated
current, and specified to liquids ingress protection category IPX5. Install the
pipes (C and C1) carrying water to and from the boiler as indicated.
HEAT EXCHANGER SPECIFICATIONS
Minimum output of boiler
Maximum flow of recirculation pump (P)
Minimum head of recirculation pump (P)
Max water temperature in boiler
Boiler pipe connections
9
ELECTRICAL CONNECTIONS
Make the connection to the a.c. power supply at the terminal box (D) provided
on the minipool.
Electrical connections must be made in compliance with safety regulations, as
indicated in the preinstallation data sheet (step 2).
The size of the power cable and the relative clamp must be selected according
to the current load, the distance from the junction box and the way the cable is
laid and routed.
The jobs of holing the terminal box and selecting and fitting the IPX5 clamp are
the responsibility of the installer.
Having made all the connections, check that the system operates correctly
(see user manual - STARTING UP FIRST TIME).
CAUTION: POWER UP THE ELECTRICAL EQUIPMENT ONLY AFTER THE
MINIPOOL HAS BEEN FILLED WITH WATER.
Refit the panels to the minipool, first the corners, then the sides, being certain to
match the reference numbers on the panels and the frame (see steps 5a-5b).
10
FITTING WOOD PANELS (Art. 612N)
A - Take the bars supplied and fit them to the four corners of the pool.
B - Locate each corner panel under the rim of the pool.
C - Locate the side frames under the rim and fix them to the corner
panels with the screws provided.
D - Locate the wedges under the corners to lift the panelling.
Draw out the bars and locate a corner bolt in the hole of each bar.
E - Bring the assembled frames up snugly against the rim, without
forcing, by jacking the bolts at the four corners.
F - Fit the panel (4), aligning it on the porthole of the minipool, and
secure with the screws.
G - Fit the side panels (in the order indicated: 1-2-3) and secure with the
screws.
H - Slip the retaining straps through the loops of the canvas.
L - Pass each strap through the loop at the bottom of the corresponding
corner panel and fasten the clasp.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1600 l/h
. . . . . . . . . . . . . . . . . . .
1,8 m.c.a.
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GB
7 Kw
80°C
3/4"
19