INSTRUCTIONS FOR INSTALLATION Art. 608 - 609
The product must be installed exactly as supplied by Teuco, otherwise warranty will be invalidated.
The directions for installation must be observed to the letter, as must those concerning recommended materials and the accessories supplied
with the product.
Electrical connections must be carried out in compliance with national safety regulations, as indicated in the preinstallation data sheet.
This manual constitutes an integral part of the product and must be kept for future reference.
Data and specifications indicated are not binding on the company: Teuco Guzzini SpA reserves the right to make such changes as are
deemed appropriate without prior notice and without any obligation to update.
This product is intended for home use. In the event of a Teuco minipool being commissioned for public use, procurement managers must
ensure compliance with all statutory regulations governing safety, water treatment and utility systems normally in force in the country of
installation.
4
REMOVING THE COVER
Remove the cover (art. 609 only: unhook the retaining straps at
the four corners).
The cover is not intended to carry weights.
Do not sit, step or lie on the cover.
Do not place objects on the cover.
The canvas can be dangerous if not secured or properly
closed.
Failure to follow the instructions for securing the canvas
can result in danger to the user.
Remove the canvas completely before stepping into the
pool, otherwise there is a risk of being trapped.
5
A
REMOVING THE SIDE PANELS (Art. 609)
Undo the screws (Z) at the bottom of the side panels, then
remove each panel by gripping at the base and pulling upwards
to release the clips (Y) from their sockets.
5
B
REMOVING THE CORNER PANELS (Art. 609)
Remove the corner panels of the minipool by gripping each one
at the base and pulling upwards to release the clips (Y) from
their sockets.
6
A
FITTING THE LIFTING BARS
Fit the lifting bars to the corners of the frame and secure in
place with the nuts and bolts provided.
NEVER LIFT THE MINIPOOL BY THE RIM OR BY THE
PIPELINES. THE MINIPOOL MUST NEVER BE LIFTED
WHEN FULL OF WATER.
6
B
PLACEMENT
When lifting and placing the minipool, use slings of
suitable load capacity at least 4 metres in length (distance
from the bars on the minipool frame to the lift hook).
Slip the slings over the bars (B) and proceed to lift the minipool,
then place it on the selected site (the weight of the minipool
when empty is approximately 300 kg).
Remove the bars (B) and keep handy for future use, if needed.
7
PLUMBING CONNECTIONS
DRAIN CONNECTION
The Teuco minipool has a gate type drain valve with a
ø 40 mm connection.
Connect the valve to the main drain by way of a trap (see
preinstallation data sheet - step 2).FILL CONNECTION
The recommended method of filling the Teuco minipool is to
use a hose (taking care not to immerse the end as this could
cause a reflux of water back into the main).
WARNINGS
8
HEAT EXCHANGER CONNECTIONS
The minipool is provided with a switch box (M) containing a relay
with a "normally open voltage-free" contact (3A Max - spare
terminals connected to Black and White conductors) that can be
used as on/off switch control for a boiler, a recirculation pump, a
zone valve or other appliance/component. The electrical
connection to the box must be permanent, able to handle the rated
current, and specified to liquids ingress protection category IPX5.
Install the pipes (C and C1) carrying water to and from the boiler
as indicated.
HEAT EXCHANGER SPECIFICATIONS
Minimum output of boiler
Maximum flow of recirculation pump (P)
Minimum head of recirculation pump (P)
Max water temperature in boiler
Boiler pipe connections
9
ELECTRICAL CONNECTIONS
Make the connection to the a.c. power supply at the terminal box
(D) provided on the minipool.
Electrical connections must be made in compliance with safety
regulations, as indicated in the preinstallation data sheet (step 2).
The size of the power cable and the relative clamp must be
selected according to the current load, the distance from the
junction box and the way the cable is laid and routed.
The jobs of holing the terminal box and selecting and fitting the
IPX5 clamp are the responsibility of the installer.
Having made all the connections, check that the system
operates correctly (see user manual - STARTING UP FIRST
TIME).
CAUTION: POWER UP THE ELECTRICAL EQUIPMENT ONLY
AFTER THE MINIPOOL HAS BEEN FILLED WITH WATER.
Refit the panels to the minipool, first the corners, then the sides,
being certain to match the reference numbers on the panels and
the frame (see steps 5a-5b).
10
FITTING WOOD PANELS (Art. 609N)
A - Take the bars supplied and fit them to the four corners of the pool.
B - Locate each corner panel under the rim of the pool.
C - Insert the dowels of the top rails in the matching holes of the corner
panels (fig.A).
Fix the top battens (fig.B1) and the bottom batten (fig.B2) to the
brackets with the screws provided.
D - Lift the panelling and rest on the bars.
Bring the assembled frames up snugly against the rim, without forcing,
by working the bolts at the four corners.
E - Fix the side panels with the screws provided.
F - Slip the retaining straps through the loops of the canvas.
G - Pass each strap through the loop at the bottom of the
corresponding corner panel and fasten the clasp.
- 609N
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GB
7 Kw
1600 l/h
1,8 m.c.a.
80°C
3/4"
17