GENERAL WARNING

This hood has been developed and produced in accordance with
DS/EN 60335-1.
This hood is only suitable for use in private households; any
other use will invalidate the warranty.
All installations must be carried out by a qualified technician in
accordance with the instructions set out by Thermex Scandina-
via A/S (Thermex) and the Laws in force.
Thermex disclaims any liability for damage resulting from im-
proper installation, assembly, operation or incorrect settings.
BEFORE INSTALLATION/OPERATION
check the hood for transport damage, defects and missing
parts immediately upon receipt.
Transport damage should be reported immediately to the
transport company and Thermex upon receipt.
Any defects and/or missing parts should be reported to Ther-
mex within 8 days of receipt and prior to installation/operation.
INSTALLATION
The hood is designed to operate at 230 volts ± 10% ~ 50 Hz in
accordance with EN 50160
connect the hood with the attached plug. NOTE: If the plug has
an Earth terminal, the hood MUST be earthed.
For models with an external motor it is important NOT to use
common zero when installing the hood and motor, as this will
affect operation.
when using an external motor from another supplier, the mo-
tor MUST be compatible with the selected hood. Failure to
comply with this will invalidate the warranty.
The hood must not be connected to the mains before installa-
tion is complete.
The air must not be discharged from the hood into a pipe used
for extraction from devices using gas or other combustible ma-
terials. Such devices must have a separate vent.
The national legislation on air emissions must be observed.
Always use the original exhaust measurements. Reduction of
the exhaust size will reduce performance and increase sound
levels.
The exhaust from the hood to the outside should be as short as
possible in order to maximise the efficiency of the hood.
The number of bends on the exhaust should be minimal in or-
der to maximise the efficiency of the hood.
Thermex recommends that vent hoses insulated against no-
ise and condensation for all bushings in unheated rooms are
always used.
Thermex recommends using a silencer when flexible hoses are
used in order to minimise sound levels.
when using flexible hoses, always ensure that they have been
fully extended in order to minimise air resistance and thereby
maximise suction performance.
Different materials require different rawlplugs and screws.
Rawlplugs and screws suitable for the material onto which the
hood will be mounted on must be used.
If the instructions for the installation of screws and fittings are
not followed, it may result in electrical shock.
The minimum distance to gas hobs from the burner's edge to
the underside of the hood MUST be a minimum of 65 cm in
accordance with EN 60335-2-31.
For cupboard-integrated, suspended and wall-mounted hoods,
Thermex recommends that the distance between the hob and
cooker hood is between 50 cm and 70 cm in order to ensure
maximum suction.
Always check the minimum distance between the hob and the
cooker hood, as indicated in the instructions for the hob. The
instructions for the hob MUST be observed if a greater distance
than that recommended by Thermex is indicated in this ma-
nual.
Thermex recommends that the distance between the hob and
the hood should not exceed 3 meters for ceiling-integrated mo-
dels.