Elvox EAM4 Manual Del Usuario página 13

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 22
EKKO
RESPECT THE MEASURES WITH 2 MECHANICAL STOPPERS
L
A
α
Min.÷Max
max
1÷1,80
45
1,81÷2,20
45
90°
2,21÷2,50
70
2,51*÷3,00*
70
L
A
α
Min.÷Max
max
1÷1,80
1,81÷2,20
110°
20
2,21÷2,50*
MECHANICAL STOPPER ADJUSTMENT
To adjust the stoppers you have to follow the scheme (Fig. 12).
To set the opening limit it's enough to fix the stopper (A) in the needed
position by tightening the 8mA screw with a n.13 key.
To obtain the desired closing limit you must adjust the stopper (B)
(OPTIONAL) in the needed position and tighten it as for stopper (A).
EMERGENCY RELEASE
To move the gate manually it is necessary to release the operator inserting
the special key and turning it 2 times in the anti-clockwise sense (Fig. 14).
In order to carry out the manual operation of the gate leaf the followings
must be checked:
- That the gate is endowed with appropriate handles;
- That these appropriate handles are placed so to avoid safety risks for
the operator;
- That the physical effort necessary to move the gate leaf should not be
higher than 225 N, for doors/gates for private dwellings, and, 390 N for
doors/gates for commercial and industrial sites ( values indicated in 5.3.5
of the EN 12453 norm).
ELECTRICAL SAFETY DEVICES
The installation must be installed according to the current regulations and
laws.
It is recommended that the following electronic control units be used:
- ECA8 for 1 or 2 single-phase EKKO 350A.
For connections and technical data of accessories refer to the appropriate
booklets.
CONNECTION TO THE POWER SUPPLY
In EKKO 350A unit, terminals 1-2-3 of the motor cable must be connected
respectively to terminals open-close-common of the control panel.
WARNING!
The length of connection cables from the motors to the control panel unit
must not exceed 15 m.
The wire section of the motor power supply must be 1.5 mm
the accessories must be 0,75 mm
FORCE ADJUSTMENT
EKKO 350A requires an ECA8 electronic control panel, equipped with
electronic force regulator.
MAINTENANCE
To be undertaken only by specialized staff after disconnecting power
supply.
Lubricate the hinges and check the oil level and thrust force generated by
the operator on the gate once a year.
Lubricate the nut screw with silicon grease every two years.
EN
B
C
D
E
100
100
775
90
110
110
775
90
140
110
775
115
160
140
775
115
B
C
D
E
90
140
775
90
100
130
775
90
110
140
775
115
, whilst that of
2
.
2
MECHANICAL STOP - OPTIONAL
Code EAX3
T
Optional mechanical stop to stop closing, if the gate is not fitted
ANT
COL
with a floor stop (Fig. 11).
sec
14
A
S3-Y
18
A
S3-X
20
B
S1-Z
25
B
S1-Y
T
ANT
COL
sec
20
A
S1-Z
21
A
S2-Y
24
B
S1-Y
11
12
13
14
11
Tabla de contenido
loading

Este manual también es adecuado para:

Eam4.120

Tabla de contenido