Operating instructions SATA filter 100 prep
2.2. Filter stage (B):
A filter cartridge in stage B filter separates tiny particles according to the filtration capacity
of the cartridge used.
Filtration capacity 0,1 µm: 99,998 % separation, relating to particles > 0,1 µm
2.3. Filter stage (C):
The activated charcoal filter unit, filter stage C, is identically designed as the filter stage (B).
The only difference is the filter cartridge which is installed in the activated charcoal filter unit
(Art.-No. 157362). When using an activated charcoal filter unit, please make sure that a
condensate separator and a fine filter stage is installed upstream.
2.4 Pressure regulation valve (D)
The pressure regulation valve (2) allows fine adjustment of the outlet pressure; maintaining
a constant pressure value with hardly any fluctuations.
The pressure regulation valve is equipped with a ball tap, connection thread G ¼.
2.5. Filter Cartridges
Typ:
Sinter filter cartridge
Sinterd bronze 5 µm,
surface area 100 cm²,
solvent regenerable
Replacement interval every
six months
Art. No. 22160
In case of extreme contamination, filters should be checked and, if necessary, replaced
more frequently. The sintered bronze filter and the filter housing tube (4, 7) must be clea-
ned every six months at the latest, if necessary, replace sintered bronze filter cartridge.
Saturated filter cartridges bear the danger of functional defaults during painting resp. affec-
ting the painter's health while using supplied-air respirator systems.
3. Construction
1
Pressure regulation T handle
2
Diaphragm and pressure regulation
valve (not illustrated)
3
Air inlet fitting G 1/2 inside thread
4
Filter housing tube, stage A
5
Integral automatic condensate discharger
IX.2
Fine filter cartridge, Poly-
propylene Micro Fibre layer
Surface area 300 cm² Filtering
capacity 0,1 µm 99,998 %
separation, relating to particles
> 0,1 µm, non-regenerable
Replacement interval every
six months
Art. No. 148270
6
7
8
9
10 Label filter exchange „fine filter"
11 Sticker filter exchange „activated char
Activated charcoal cartridge
non-regenerable
Replacement interval every
three months
Art. No. 157362
Condensate drain hose (not illustrated)
Filter housing tube, stage B and C
Mounting angle (not illustrated)
Label filter exchange „sintered filter"
- yellow -
- blue -
coal" – black –
Tabla de contenido
loading

Este manual también es adecuado para:

Filter 101 prepFilter 103 prep

Tabla de contenido