For optimal use, the welding installation must respect the following positioning constraints for correct cooling.
The power source is not designed to be slung alone.
Only the complete installation mounted on the workshop trolley W000279927 and quipped with the tube handle option W000279930 and the
swivel leg option W000279932 can be slung, without the gas bottle. In that case, use exclusively the slinging rings designed for this use of
the swivel leg option W000279932.

2.5. STARTING UP

The main switch is located at the rear of the generator. Flip this switch to turn the machine on. This switch must never be
flipped during welding. At each start-up, the generator displays the software version, the power and the connected optional
device, as relevant of the power source.
When starting up for the first time, the configuration is required cf § 6.1.