Note: If the setting exceeds the capacity of the source, the curve appears red
Remark:
With the SYN mode, the wire speed of the Hotstart / Softstart step is tuned relatively to the wire speed of the welding step (∆ ±70 %), the real
speed is shown for information in grey tint, and is directly tunable with the MAN mode: wire speed (m/min) [1.0 ; 25.0].
3. Welding
This menu allows refining of the tuning of the welding step.
Remark:
Once you've chosen the mode, the main welding parameters are actualized. It is then possible to tune the parameters of each mode directly from
the main welding tuning page.
Advanced Sequencer
Sequence the welding phase in two regimes 1 and 2, which can have different arc transfers: Flat or Pulsed.
The arc transfer of the regime 1 is the one selected on the synergy bar of the main welding tuning page.
Intermittent mode
(
The welding is made intermittently by a succession of times ON and times OFF.
Remark:
You can choose to realize the hotstart only on the first time ON in the menu:Configuration > Installation > Cycle.
Step mode
(
)
Bearing change by a short press on the trigger
Program call during welding
Once you activate this option, you can call programs with the trigger while you're welding. See § 4.3. page 23. Program Management.
Remark:
You can activate the program call out of welding in the menu: Configuration > Installation > Cycle
DIGIWAVE II
Softstart
The softstart phase can be pre-set for the start of the weld, allowing a limited wire speed with
low energy.
(
+
)
The timing of regimes 1 and 2 are independent and allow tuning of a dissymmetrical cycle. T(s) [0.1 ; 5.0]
)
The timings of step ON and OFF are independent and allow tuning a dissymmetrical cycle. T(s) [0.5 ; 10.0]
(
)
Paramètres principaux de soudage du palier de Hostart/Softstart.
Main welding parameters of the regimes 1 and 2
Variables :
Temps de palier : T(s) [0.00 ; 10.00]
Temps de transitions : T(s) [0.00 ; 10.00]
Variables :
Arc transfer regime 2: Transfer2
T(s)
Transit time
[0.00 ; 1.00]
Variables :
Main welding parameters
Variables :
Step number [2 ; 4]
Main welding parameters of every step