BTL7-A/C/E/G5_ _-M_ _ _ _-B/Z-DEX_-K_ _/KA_ _
Micropulse Transducer - Rod Style
2
ATEX safety notes (continued)
2.4.4
Operator documents
Zone classification in the system is the responsibility of the
operator and must be documented in an explosion
protection document. This document must also contain
the hazard analysis and assessment, proof of training,
maintenance plans and other documents as required
under Directive 1999/92/EC.
We expressly recommend including the user's guide in the
operator's documentation. For safety reasons, it must be
taken over completely and without any changes.
2.5
Assembly, installation, and setup
Assembly, installation, and setup of the transducer must
not be done in an explosive atmosphere.
The installation distance of the flat gap to fixed parts that
are not a part of the equipment must be at least 2 mm.
The BTL7-A-CB02 adjusting box (accessories) may only
be installed during the adjustment phase and must be
uninstalled before operating the transducer.
Protect the transducer from damage and wear. In addition
to mechanical protection, this also includes precautions to
prevent non-permissible operating conditions and damage
due to environmental influences.
2.6
Maintenance, inspection, repair
The measuring principle used in this transducer is
maintenance-free and wear-free. The operator must
regularly inspect the transducer for signs of damage or
malfunctions in line with the operating conditions and
environmental influences. If any damage or wear is found,
the transducer must be immediately taken out of
operation.
Only service technicians from BALLUFF GmbH may repair
defective transducers. Intervention in the product by the
operator is not permitted due to safety reasons.
The transducer's housing may not be opened or loosened!
This is why the following warning label is affixed over a gap
in the housing.
8
english
Ignition protection "d"
Flameproof enclosure
2.7
General safety notes
Neither the 6 mounting screws for the cover/flange, nor the
cable fitting, may be loosened!
Protect the transducer from damage and wear. In addition
to mechanical protection, this also includes precautions to
prevent damage due to environmental influences.