Fixing The Heater To The Floor; Safety Railing; Installation Of Control Unit And Sensor; Montage Des Saunaofens Am Boden - Harvia Vega BC105 Instrucciones De Instalacion Y Uso

Calentador eléctrico para sauna
Tabla de contenido
EN

3.2. Fixing the Heater to the Floor

The heater is fixed to the floor at its two legs, at
the legs' fixing points.
Before fixing the heater, the minimum safety dis-
tances to inflammable materials should be taken into
consideration. See table 1 and figure 3.

3.3. Safety Railing

If a safety railing is built around the heater, the mini-
mum distances given in table 1 must be observed.
Model
A min.
A max.
Modell
mm
BC105
50
BC135
80
BC165
100
Figure 3.
The heater's safety distances
Abbildung 3. Sicherheitsabstände des Saunaofens

3.4. Installation of Control Unit and Sensor

Detailed instructions for the installation of both the
unit and the sensor are delivered with the control unit.
26
B min.
C min.
mm
mm
mm
150
50
1250
180
80
1450
200
100
1450
DE

3.2. Montage des Saunaofens am Boden

Der Saunaofen wird mit zwei Füßen am Boden mon-
tiert, an den Befestigungsstellen der Füße.
Vor der Montage des Saunaofens müssen die Min-
destsicherheitsabstände zu brennbaren Materialien
beachtet werden. Siehe Tabelle 1 sowie Abbildung 3.
3.3. Schutzgeländer
Falls um den Saunaofen ein Schutzgeländer gebaut
wird, muß dies unter Berücksichtigung der in Tabell 1
angegebenen Mindestsicherheitsabstände geschehen.
D min.
mm
50
50
Connection cable
50
Anschlusskabel
Figure 4.
Abbildung 4. Anschluß des Saunaofens
3.4. Installation des Steuergeräts und des
Fühlers
Genaue Informationen zur Installation des Steuerge-
räts und des Fühlers werden mit dem Steuergerät
geliefert.
Connections of the heater
Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Bc135Bc165

Tabla de contenido