1.4
Technical Data
Model
Load capacity
Lifting time (4,000 kg)
Lowering time (4,000 kg)
Electrical system
Control voltage
Motor
Upstream fuse
Connection cable
Protection type
Working pressure ²
Recommended hydraulic oil
Oil quantity
Floor anchor
Number of anchors
Recommended compressed air
connection
Permissible sound level
Weight
²
The factory-set working pressure is adjusted to the maximum rated power. The pressure relief valve
must not be tampered with. Changing the settings can lead to serious damage.
If the specified rated load cannot be lifted, please contact our
service team.
® Copyright ATH-Heinl GmbH & Co. KG, All rights reserved / Misprints and technical changes reserved / As of: 2020-03
All manuals and user guides at all-guides.com
Summer: HVLP-D 46 (e.g.: ENI Precis HVLP-D 46)
Bolt anchor: M16 x 180 (e.g.: Atrion ABL-W 16-060-180)
Compound anchor: M16 x 190 (e.g.: Atrion AVA-W 16-045-190)
Manufacturer ATH-Heinl GmbH & CO.KG
- 8 -
ATH-Four Lift 65
6,500 kg
48 s
48 s
3/400V/50Hz
DC24V
3.0 kW
3 C 16 A
Min. 5 x 2.5 mm²
IP 43
Approx. 160 bar
Winter: HVLP-D 32
Approx. 18 l
16 units
8 bar
≤ 78 dB
2,100 kg