STORAGE & MAINTENANCE
ENGINE:
The engine instructions that accompany your unit detail specific  
procedures for maintenance of the engine.  Following the engine   
manufacturer's recommendations will extend engine work life.
PUMP:
The pump oil must be changed after the first 25 hours of operation.
Once the initial oil change has been completed, it is recommended 
the  oil  be  changed  every  3  months  or  250  hour  intervals.    If  oil 
appears  dirty  or  milky,  changes  may  be  required  at  a  greater 
frequency.  Use Mi-T-M pump oil #AW-4085-006. Fill only to the 
center of the oil sight glass.  DO NOT OVERFILL!
NOZZLES: Water flow through the spray nozzle will erode the orifice, making
it larger, resulting in a pressure loss.  Nozzles should be replaced 
whenever pressure is less than 85% of the maximum. The frequency 
of replacement will depend upon such variables as mineral content 
in the water and number of hours the nozzle is used.  
QUICK COUPLERS:  There is an o-ring seal inside the female quick coupler.   
This  o-ring  will  deteriorate  or,  if  the  unit  is  allowed    to  pump 
without  the high pressure hose or nozzle attached, the o-ring may 
be blown out occasionally.  Simply insert a replacement o-ring to 
correct the leak.  (Additional o-rings can be purchased from your 
dealer.)
LEAKS: 
Promptly  eliminate  any  leaks  found  in  the  pumping  system  by   
removing  suspect  parts,  applying  thread  sealant  to  the  threads   
and reinstalling.  
NOTE: If using teflon tape, be certain no tape gets inside any plumbing to
prevent the possibility of a plugged spray nozzle.