*Parameter
SET1
.
│ ├
.EP
Endpoint 1
│ ├
.UnitEp
│ ├
.Dyn
│ ├
.UnitDyn
│ ├
.MaxRate
│ ├
.MinRate
│ ├
.Stop
│ │ ├
.Type
│ │ ├
.Drift
│ │ ├
.Time
│ │ ├
.StopT
SET2
.
TitrPara
.
│ ├
.Direction
│ ├
.XPause
│ ├
.Start V
│ │ ├
.Type
│ │ ├
.V
│ │ ├
.Factor
│ │ ├
.Rate
│ ├
.Pause
│ ├
.ExtrT
│ ├
.MeasInput
│ ├
.Ipol
│ ├
.Upol
│ ├
.PolElectrTest
│ ├
.Temp
│ ├
.TDelta
StopCond
.
│ ├
.VStop
│ │ ├
.Type
│ │ ├
.V
│ │ ├
.Factor
│ ├
.FillRate
Statistics
.
│ ├
.Status
│ ├
.MeanN
│ ├
.ResTab
│ │ ├
.Select
│ │ ├
.DelN
Presel
.
│ ├
.Cond
│ ├
.DriftDisp
│ ├
.DCor
│ │ ├
.Type
│ │ ├
.Value
│ ├
.IReq
│ ├
.SReq
│ ├
.LimSmplSize
│ │ ├
.Status
│ │ ├
.LoLim
│ │ ├
.UpLim
│ ├
.ActPulse
798 MPT Titrino
Tree part "Parameters for SET"
Control parameters for EP1
depends on meas.quant.
Unit of endpoint
Dynamics
Unit of dynamics
Maximum dosing rate
Minimum dosing rate
Titration stop
Type of stop criterion
Stop drift
Switch-off delay time
Stop time
Control parameters for EP2, as for EP1
Titration parameters
Titration direction
Waiting time before start volume
Start volume
Type of start volume
Volume for absolute start volume
Factor for relative start volume
Dispensing rate for start volume
Waiting time after start volume
Extraction time
Measuring input
Polarization current
Polarization voltage
Test for polarized electrodes
Titration temperature
Time interv. for meas.acquisition
Stop conditions
Stop volume
Type of stop volume
Volume for absolute stop volume
Factor for relative stop volume
Filling rate
Statistics
Status of statistics calculation
No. of individual determinations
Result table
Deletion of individual results
Preselections
Conditioning
Display of drift during cond.
Drift correction
Type of drift acquisition
Drift value for manual drift corr.
Request of Id's after start
Request of smpl size after start
Limits for sample size
Status of limit control
Lower limit
Upper limit
Output of a pulse
3.2 Remote control commands
3.2.2.28.
read only
depends on meas.quant. 3.2.2.29.
read only
0.01...10...150, max.
0.01...25.0...9999
drift, time
1...20...999
0...10...999, inf
0...999 999, OFF
+, -, auto
0...999 999
abs., rel., OFF
0...999.99
0...±999 999
0.01...150.0, max.
0...999 999
0...999 999
1, 2, diff.
0...1...±127
0...400...±1270
ON, OFF
-170.0...25.0...500.0
1...2...999 999
abs., rel., OFF
0...99.99...9999.99
0...±999 999
0.01...150.0, max.
ON, OFF
2...20
original,delete n,delete all
1...20
ON, OFF
ON, OFF
auto, man., OFF
0.0...99.9
id1, id1&2, all, OFF
value, unit, all, OFF
ON, OFF
0.0...999 999
0.0...999 999
first, all, cond., OFF
ditto
ditto
ditto
ditto
3.2.2.30.
ditto
ditto
ditto
3.2.2.31.
3.2.2.32.
3.2.2.15.
ditto
ditto
ditto
3.2.2.16.
3.2.2.33.
3.2.2.18.
ditto
ditto
ditto
3.2.2.19.
3.2.2.34.
3.2.2.20.
ditto
ditto
3.2.2.23.
3.2.2.24.
ditto
ditto
ditto
3.2.2.35.
ditto
ditto
ditto
3.2.2.26.
ditto
3.2.2.27
ditto
ditto
ditto
3.2.2.28.
81