5. Eliminate the lime that in time deposits inside the hydraulic circuit of the machine, by putting some
anti-lime solution in the solution tank and leave it for some hours. Then empty the tank and rinse. It is
enough to perform this operation every 6-8 months.
6. Periodically have the carbon brushes of the vacuum motor checked. Contact a technical assistance
for this operation.
Technical specifications
Dimensions
Weight
Volume of recovery tank
Volume of solution tank
Overall Power adsorbed
Pump max pressure
Pump max water flow
Pump nominal power
Motor max depression
Motor max airflow
Motor nominal power
Cleaning width
Number of spray nozzles
Performances
Hose length
Troubleshooting section
PROBLEM
The machine does not work.
The pump does not work.
The vacuum motor doesn't work motor switch or motor is broken.
Spraying is not regular
Vacuum is not good enough
1210
30x42x53 cm
15 Kg
14 Liter
14 Liter
1070 W
4 bar
1,5 l/min
70W
3000mm
50 l/sec
1500W
270mm
1
60mq/h
2,5m
POSSIBLE CAUSE
A switch or wire is broken.
The power cable is broken.
The switch or wires are broken.
Pump is broken.
Thermal protection has stopped
the motor.
Internal wires disconnected.
Dirty nozzles.
Solution tank is almost empty.
The motor filter between the 2
tanks is dirty.
The cuff connecting the vacuum
hose to the machine or to the
accessory is not tightened.
Home
Find... Go To..
1215
50x92x98 cm
25 Kg
30 Liter
30 Liter
1280 W
9 bar
4,5 l/min
80W
3000mm
60 l/sec
1500W
300mm
3
70mq/h
3,5 m
SOLUTION
Contact technical assistance.
Contact technical assistance.
Contact technical assistance.
Contact technical assistance.
Contact technical assistance.
Let the motor cool down before
using it again.
Contact technical assistance.
Clean the spray nozzles of
the accessory.
Fill the solution tank.
Clean the motor filter.
Tighten the connection
between cuffs and vacuum
hose.
5