Electrical Requirements, 120 V Electric Models - U.s.a. And Canada (24" (69 Cm) Models Only); Electrical Requirements, 240 V Electric Models - Canada - Whirlpool WETLV27HW Instrucciones De Instalación

Lavadora/secadora eléctrica de 24" (61 cm) y eléctrica y de gas de 27" (69 cm)
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Electrical Requirements,
120 V Electric Models – U.S.A.
and Canada (24" (69 cm)
Models Only)
It is recommended that a separate circuit breaker
Ƀ
serving only this appliance be provided.
120 V models are equipped with a power supply
Ƀ
cord having a 3 prong grounding plug intended
to be plugged into a 20 A 5-20R wall receptacle.
To minimize possible shock hazard, the cord
Ƀ
must be plugged into a mating, 3 prong,
grounding-type outlet, grounded in accordance
with local codes and ordinances. If a mating outlet is not
available, it is the personal responsibility and obligation of the
customer to have the properly grounded outlet installed by a
qualified electrician.
If codes permit and a separate ground wire is used, it is
Ƀ
recommended that a qualified electrician determine that
the ground path is adequate.
Check with a qualified electrician if you are not sure the
Ƀ
washer/dryer is properly grounded.
Do not have a fuse in the neutral or ground circuit.
Ƀ
120 V, 60 Hz AC only, 20 A fused electrical supply is required.
Ƀ
A time-delay fuse or circuit breaker is recommended.
It is your responsibility:
To contact a qualified electrical installer.
Ƀ
To be sure that the electrical connection is adequate and in
Ƀ
conformance with the National Electrical Code, ANSI/NFPA
70–latest edition or the Canadian Electrical Code,
C22.1–latest edition and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association, One Batterymarch Park,
Quincy, MA 02269 or Canadian Standards Association, 178
Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.
Do not use an extension cord.
Ƀ
12
Electrical Requirements, 240 V
Electric Models – Canada
It is your responsibility:
To contact a qualified electrical installer.
Ƀ
To be sure that the electrical connection is adequate and in
Ƀ
conformance with Canadian Electrical Code, C22.1–latest
edition and all local codes. A copy of above codes standard
may be obtained from: Canadian Standards Association,
178 Rexdale Blvd., Toronto, ON M9W 1R3 CANADA.
To supply the required 4-wire, single-phase, 120/240 V,
Ƀ
60 Hz AC only electrical supply on a separate 30 A
circuit, fused on both sides of the line. A time-delay fuse
or circuit breaker is recommended. Connect to an individual
branch circuit.
This dryer is equipped with a UL Listed
Ƀ
and/or CSA International Certified Power
Cord intended to be plugged into a standard
14-30 R wall receptacle. The cord is 5 ft
(1.52 m) long. Be sure wall receptacle is
within reach of dryer's final location.
If using a replacement power supply cord, it is recommended that
you use Power Supply Cord Replacement Part Number 9831317.
For further information, please reference service numbers located
in "Assistance or Service" section of your Use and Care Guide.
5-20R
receptacle
4-wire receptacle
(14-30 R)
Tabla de contenido
loading

Este manual también es adecuado para:

Wet4124hw

Tabla de contenido