8) Trouble: no cold air under COOL "K" mode.
Analysis:
a) room temperature is lower than set temperature. It is a normal phenomenon, the machine will auto-switch while the room
temperature is higher than the set temperature.
b) Device enters into anti-frost protection. The device will auto switch after anti-frost protection is over.
9) Trouble: LED displays failure code "E2"
Analysis:
a) room temperature sensor fails or damages. Replace the room temperature sensor by service provider.
10) Trouble: LED displays failure code "E3"
Analysis:
a) the evaporator oil pipe sensor fails or damaged. Replace the evaporator coil pipe sensor by service provider.
11) Trouble: LED displays failure code "E4"
Analysis:
a) water-full warning. Drain out the water.
CLEANING AND MAINTENANCE
Device maintenance
1. Turn off the device first before disconnecting from power supply.
2. Wipe with a soft and dry cloth. Use lukewarm water below 40°C to clean if the appliance is very dirty.
3. Never use volatile substance such as gasoline or polishing powder to clean the device.
Air filters maintenance
It is necessary to clean the air filters every 2 weeks if the device operates in an extremely dusty environment. Clean as follows:
1. Stop the device first, push up both air filters (Picture F).
1.a. To take away the first air filter draw out in the right side the filter by handle shown at picture F1.
1.b. To take away the second air filter pull the cover outside toward you in place shown at picture F2. Now 4 latches will released
easy.
2. Clean and reinstall both air filters before switch on again.
3. If the dirt is conspicuous, wash it with a solution of detergent in lukewarm water. After cleaning dry it in a shaded and cool place,
then reinstall it.
Maintenance after seasonal using
1. If the device will not use for longer time, be sure to pull out the rubber plug of upper cooler drain hole (8) and the rubber plug
down cooler drain hole (9) of the drain port, in order to drain the water.
2. Keep the appliance running with fan only for a half day during a sunny day to dry the appliance inside and prevent from going
moldy.
3. Stop the device and pull out the power cord plug, then take out the batteries of remote controller and store device properly.
4. Clean the air filter and reinstall it.
5. Remove the air hoses and store them properly, and cover the hole tightly.
TECHNICAL DATA:
Cooling capacity (BTU): 9000 BTU / hour
Cooling capacity (watts): 2600W
Energy consumption (cooling) W: 950 W
Heating capacity (BTU): 7000 BTU / hour
Heating capacity (watts): 2000W
Energy consumption (heating) W: 750 W
Voltage 220-240V~ 50Hz
Volume: <= 65dB
Air flow: 350 m3 / h
Energy class: A
Timer: 24 hours
R290 coolant weight: max. 165 grams
Caution, risk of fire.
Do NOT pierce or burn.
Be aware that the refrigerant may not contain an odour.
The maximum refrigerant charge amount: 165g.