EN
•
Make sure that parts of the body never come between moving parts. There is a risk that parts of the
body may be crushed or cut.
•
Stop immediately if the system makes strange noises or displays aberrant behaviour.
•
Stop immediately if the equipment leaks oil. Oil escaping under pressure can penetrate the skin and
cause serious injury. Go immediately to a hospital with a person which is injected with oil for medical
help. Give a specification of the oil to the medical staff.
2.6
Safety regulations with respect to maintenance
•
Wear personal means of protection when performing maintenance tasks.
•
Never work in a way that could jeopardize safety.
•
Make sure that the equipment cannot roll away or tip over. The control and drive must be switched
off and safeguarded against unexpected activation.
•
Make sure that moving parts do not move unexpectedly.
•
Used or leaked fluids, and any other products consumed during the activities, must be collected and
disposed of in a environmentally responsible way.
3
Description
3.1
Equipment
Depending on the model of hand or foot pump, it can be used for single- or double-acting hydraulic tools
operating on mineral oil and suitable for an allowable operation pressure of 720 bar. The maximum
available oil volume differs per pump. The pump can not be used for equipment which requires more oil
volume as stated in the technical specification of the particular pump.
3.1.1
Type designation
Example: HTW 1800 B
/i
Digit Example
Description
1
H
H = Hand pump
F = Foot pump
2
T
Hydraulic pump
3
W
S = Single-stage
W = Two-stage
4-7
1800
Model number
8
B
Version code
3.2
Product identification
Refer to Fig. 2 up to Fig. 6.
/i
1
Pump rod
2
Handle / foot paddle
3
Vent valve (bleeding)
4
Dipstick / refill opening
5
Pressure relief valve
6
Hydraulic oil tank
26
7
Pump rod lock
8
Couplers
9
Pump body
10
Base plate
11
Dust cap
12
Carrying handle
916.000.901_000