Electrical Connection And Ir Receiver Connection; Function Test / Mounting For The Remote Control - Truma Saphir vario Instrucciones De Uso

Ocultar thumbs Ver también para Saphir vario:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 58
230 V electrical connection
and IR receiver connection
The electrical connection must always be made by
an expert (in accordance with VDE 0100, part 721 or
IEC 60364-7-721 in Germany)! The instructions given here are
not a challenge to the lay person to carry out the electrical
connection, but serve to provide additional information for the
professional fitter whom you engage!
Unscrew 2 screws (14) and open the cover of the electronic
system.
Insert mains cable plug (15) into socket. The plug is automati-
cally provided with strain relief by engaging in a retaining lug.
The retaining lug must be lifted with a screwdriver in order to
remove the plug from the socket.
Insert IR receiver plug into socket (16).
The connection (17) is needed if the Saphir vario air con-
ditioning unit is being operated via a Truma TG 1000 sinus
power inverter (COM connection / communication a or b).
Close electronic system cover again and screw the screws (14)
back in.
The cables must be long enough for the unit to be pulled out
of the false floor with the cables attached. All cables must be
secured with cable clips!
For maintenance or repair work, an isolating device must be
provided on the vehicle side to provide all-pole isolation from
the mains, with a contact interval of at least 3.5 mm.
20
17
16
15
Function test / Mounting for the remote
control
Position the mounting for the remote control as close as
possible to the receiver (9), in order to allow for the air-condi-
tioning system to be operated without removing the remote
control from its mounting.
In conclusion, all the functions of the device need to be tested
in accordance with the Operating Instructions.
The operating instructions must be handed to the owner of
the vehicle.
loading