Exhaust Hose Installation - Daitsu APD12-AN Manual De Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Exhaust hose installation

Fig. 18
Use the screws to install
the flat mouth
Fig. 19a
Fig. 19b
Push in
Hook
Expansion
plug position
Adaptor A
Adaptor cap
49
The exhaust hose and adaptor must be installed or removed
in accordance with the usage mode.
COOL mode
FAN or DEHUMIDIIFY mode
Exhaust hose
1. Install the adaptor B and adaptor I onto the exhaust hose
2. Place the Exhaust hose over against the air outlet
Flat mouth
Flat mouth
Note:
Extend the both ends of the exhaust hose to a length of
30~50mm before install the adaptor B and adaptor I onto the
exhaust hose.
The exhaust hose can be installed into the wall
(Not applicable to the units without adaptor A, expansion
plugs and wooden screws of Accessories )
1. Prepare a hole in the wall. Install the wall Exhaust
Fig. 20
2. Attach the Exhaust hose to wall Exhaust adaptor A.
Note:
Cover the hole using the adaptor cap when not in use.
IMPORTANT:
DO NOT OVER BEND THE EXHAUST HOSE (SEE Fig.22)
max 120 CM
.
min 30 CM
Fig. 21
Fig. 22
For the first time to use the machine, take the exhaust
hose out as shown in Fig.18.
as shown in Fig.19a or Fig.19b. Refer to the previous
pages for window kit installation.
opening hook and flat the other end (See Fig.20) for
quick installation.
adaptor A onto the wall (outside) by using 4 expansion
plugs and wooden screws, be sure to fix thoroughly. (See
Fig.21).
The exhaust hose can be compressed or extended
moderately according to the installation requirement, but
it is desirable to keep the hose length to a minimum.
Install
Remove
Tabla de contenido
loading

Este manual también es adecuado para:

Apd12-ant

Tabla de contenido