Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 47
TFA_No. 60.2562.01GB_Anleitung
18.08.2021
BOXX2 – Radio-controlled alarm clock with indoor climate
• Interrupt the reception by holding and pressing the ▼ button again. The DCF reception symbol disappears.
• The DCF reception always takes place daily at 1:00, 2:00 and 3:00 o'clock in the morning. If the reception is not success-
fully received, another DCF reception will take place the next full hour (up to 2 times).
• There are three different reception states:
Symbol flashing – reception is active
Symbol solid – reception is successful
no symbol – no reception/time was set manually
• If the clock cannot detect the DCF-signal (e.g. due to interference, transmitting distance, etc.), the time can be set manu-
ally. The DCF reception symbol disappears and the clock will then work as a normal quartz clock (see: Manual settings).
Note on radio-controlled time
• The time is transmitted from an atomic clock near Frankfurt am Main by a DCF-77 (77.5 kHz) frequency signal with a range
of about 1,500 km. Your radio-controlled clock receives the signal, converts it and always shows the exact time. The adjust-
ment of Daylight-Saving Time and Standard Time is also automatic.
• Make sure to avoid the vicinity of any source of interference such as computer screens, TV sets or solid metal objects. With-
in concrete walls (reinforced with steel) such as basements, the received signal is naturally weakened. In extreme cases,
please place the unit close to a window to improve reception.
16:57 Uhr
Seite 19
– 36 –
BOXX2 – Radio-controlled alarm clock with indoor climate
• During night-time, the atmospheric interference is usually less severe. A single daily reception is adequate to keep the accu-
racy deviation under 1 second.
8. Operation

8.1 Manual settings

• Press and hold the SET button for three seconds to enter the setting mode.
• The first adjustable value flashes on the display.
• Use the ▲ or ▼ button to make the desired setting.
• Confirm with the SET button and go to the next setting.
• The sequence is shown as follows:
– DCF reception ON/OFF (default: DCF ON)
– Time zone -12/+12 (default: ZONE 0H)
– Snooze interval 5/10/15 minutes (default: zZ 05)
– Optional display: Year (Y), calendar week (CW) or seconds (SEC), (default: Y)
– Hours, minutes
– Year, month, day
• Press and hold the ▲ or ▼ button in the respective setting mode for quick setting. The device will automatically quit the
setting mode if no button is pressed for 20 seconds.
– 37 –
Tabla de contenido
loading

Este manual también es adecuado para:

60.2562.01.gb

Tabla de contenido