INTRODUCTION
Tripp Lite External Battery Packs have output voltages of either 36 volts (BP36V14-2U), 48 volts
(BP48V24-2U) or 72 volts (BP72V12-2U) and are designed for use with various Tripp Lite UPS systems
equipped with external battery pack connectors. When used with the appropriate Tripp Lite UPS, they meet
UL standard 1778. The BP48V24-2U may also be suitable for use with 48V DC input telecommunications
equipment.
PACKING LIST
• Battery Pack
• BP48V24-2U only:
Alternate Front Panel
• 4 Mounting Ears
(2 black, 2 grey)
SAFETY
• Use caution when lifting Battery Packs. Because of the considerable weight of all Rackmount
Battery Packs, at least two people should assist in lifting and installing them.
• 36V and 72V Battery Packs and UPS systems use identical power cables and plugs; make
certain that your Battery Packs and UPS use the same DC voltage before connecting them.
• Suggested mounting procedures are for common rack types and may not be appropriate for all rack
configurations. User must determine the fitness of rack- and wallmount hardware and procedures
before mounting.
• When connecting multiple Battery Packs to a single UPS, the Battery Packs should be approximately
the same age.
• It is normal for sparks to occur inside external battery connectors during final battery connection.
• Do not unplug external batteries from the UPS while the UPS is operating on battery power, due to
the possibility of dangerous arcing.
• There are no user-serviceable parts inside the Battery Packs. Do not open the Battery Packs for
any reason.
• Battery Replacement must be performed by factory authorized service personnel. Because batteries
present a risk of electrical shock and burn from high short-circuit current, observe proper precautions.
Unplug the Battery Pack from the UPS before performing battery replacement. Do not short or bridge
battery terminals with any object. Use tools with insulated handles. Remove metal objects such as
watches and rings before working with batteries. Do not open batteries. Replace batteries only with
sealed lead-acid batteries of the same number, type, voltage and amp hour capacity.
• Do not dispose of batteries in a fire. The batteries are recyclable. Proper disposal of batteries is required;
refer to your local codes for disposal requirements. In the USA only, you may call 1-800-SAV-LEAD
(1-800-728-5323) for complete recycling information.
200005167 Rackmount Battery Pack Manual (Revised).p65
BP36V14-2U
BP48V24-2U
BP72V12-2U
External Battery Packs
FRANÇAIS: p. 12
• 2 Mounting Extensions
• Screws
• Wing Bolts
• Locking Nuts
• Flat Washers
Copyright © 2000 Tripp Lite. All rights reserved.
1
Owner's Manual
ESPAÑOL: p. 6
8/15/00, 12:50 PM
1
Tabla de contenido
loading

Resumen de contenidos para Tripp-Lite BP36V14-2U

  • Página 6: Introduccion

    Bancos de Baterias Externas INTRODUCCION Los Bancos de Baterías Externas Tripp Lite tienen voltajes de entrada de 36 voltios (BP36V14-2U), 48 voltios (BP48V24-2U) ó 72 voltios (BP72V12-2U) y han sido diseñados para usarlos con los diferentes no-breaks Tripp Lite equipados con conectores para bancos de baterías externas. Estas unidades, utilizadas con los no-breaks Tripp Lite adecuados, cumplen con la norma 1778 de UL.
  • Página 7: Seleccion De Color (Unicamente Modelo Bp48V24-2U)

    All manuals and user guides at all-guides.com SELECCION DE COLOR (UNICAMENTE MODELO BP48V24-2U) El modelo BP4824-2U puede ser configurado para coincidir con equipos de color negro o gris. Para equipos de color gris, utilice las orejuelas grises de montaje en el frente. Para equipos de color negro, cambie el panel frontal de la unidad e instale el panel negro incluido y utilice las orejuelas negras de montaje.
  • Página 8: Instalacion Sugerida Para Entornos De Rack De 2 Postes

    All manuals and user guides at all-guides.com INSTALACION SUGERIDA PARA ENTORNOS DE RACK DE 2 POSTES En ambos lados del Banco de Baterías, conecte una orejuela de montaje (A) con cuatro tornillos y arandelas planas (B) a los hoyos de montaje en la parte media del Banco de Baterías.
  • Página 9: Instalacion Sugerida En Forma Vertical (Torre)

    Adapter) disponible por separado a través de Tripp Lite, o utilizando uno o más Bancos de Baterías Tripp Lite modelo BP48V60-3U conectados entre sí. Los modelos BP36V14-2U o BP72V12-2U incluyen receptáculos dobles de entrada / salida en sus paneles posteriores (B). Para conectarlos a un no-break, inserte un extremo del cable desmontable (C) al receptáculo en...
  • Página 10: Guia De Resolucion De Problemas

    All manuals and user guides at all-guides.com GUIA DE RESOLUCION DE PROBLEMAS Existe un conjunto de fusibles internos en el Banco de Baterías. Si se presentara una sobrecarga severa o si ocurriera un corto circuito, uno de los fusibles se abrirá (se quemará). Esto causará que el Banco de Baterías no suministre voltaje de salida alguno independientemente de la carga conectada.