Before Starting The Equipment - EINHELL PRESSITO Manual De Instrucciones

Función dual inflador/desinflador inalámbrico/con cable
Ocultar thumbs Ver también para PRESSITO:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Have the equipment checked if necessary.
Switch off the equipment when not in use.
CAUTION!
Residual risks
Even if you use this electric power tool in
accordance with the instructions, certain
residual risks cannot be eliminated. The
following hazards may arise in connection
with the equipment's construction and
layout:
Damage to hearing if no suitable ear
protection is applied.
Danger!
This electric power tool generates an
electromagnetic fi eld during operation. Under
certain circumstances this fi eld may actively or
passively impede medical implants. To reduce
the risk of serious or fatal injuries, we recommend
persons with medical implants to consult their
doctor and the manufacturer of the medical
implant prior to using the equipment.
4.1 Data for mains-powered mode
Rated operating voltage and frequency (mains
operation) .......................... 100-120V ~ 50-60 Hz
Max. operating pressure
(infl ator/defl ator compressed air) 160 psi (11 bar)
Theoretical suction rate (infl ator/defl ator
compressed air) ................. 5.5 gal/min (21 l/min)
Output for compressed air
at 58 psi ............................. 2.6 gal/min (10 l/min)
Output for compressed air
at 102 psi ............................. 2.1 gal/min (8 l/min)
Max. volumetric fl ow for suctioning (low-pressure
blower): ........................... 100 gal/min (380 l/min)
Max. volumetric fl ow for infl ating (low-pressure
blower): ........................... 105 gal/min (400 l/min)
Infl ator/defl ator ........................ 3450 rpm (min
Blower no load speed ............ 15000 rpm (min
Rating
infl ator
suction
73W
Anl_PRESSITO_USA_SPK7.indb 13
Anl_PRESSITO_USA_SPK7.indb 13
)
-1
)
-1
blower
60W
55W
- 13 -
EN
4.2 Data for operation with a rechargeable
battery
Motor power supply: ............................18 V
Max. operating pressure
(infl ator/defl ator compressed air) 160 psi (11 bar)
Theoretical suction rate (infl ator/defl ator
compressed air) ................. 5.5 gal/min (21 l/min)
Output for compressed air
at 58 psi ............................... 2.4 gal/min (9 l/min)
Output for compressed air
at 102 psi ............................. 1.6 gal/min (6 l/min)
Max. volumetric fl ow for suctioning (low-pressure
blower): ............................. 98 gal/min (370 l/min)
Max. volumetric fl ow for infl ating (low-pressure
blower): ........................... 103 gal/min (390 l/min)
Infl ator/defl ator ......................... 3450 rpm (min
Blower no load speed ............ 15000 rpm (min

5. Before starting the equipment

Before you connect the equipment to the power
supply make sure that the data on the rating plate
are identical to the supply voltage (if operating
from the mains power supply).
Before you connect the equipment to the power
supply make sure that the data on the rating plate
are identical to the data for the rechargeable
battery (if using a rechargeable battery for
operation).
Check the equipment for damage which may
have occurred in transit. Report any damage
immediately to the transport company which
was used to deliver the inflator/deflator.
Make sure that the intake air is dry and
dustfree.
Do not install the inflator/deflator in a damp or
wet room.
The inflator/deflator may only be used in
suitable rooms (with good ventilation and
an ambient temperature from 41°F a 104°F
(+5° a +40°C)). There must be no dust, acids,
vapors, explosive gases or inflammable
gases in the room.
The inflator/deflator is designed to be used in
dry rooms. It is prohibited to use the inflator/
deflator in areas where work is conducted
with sprayed water.
Operate the equipment only on a firm, level
surface.
)
-1
)
-1
24.03.2020 11:14:21
24.03.2020 11:14:21
Tabla de contenido
loading

Este manual también es adecuado para:

4020463

Tabla de contenido