Warning! When using the equipment to infl ate
objects, check the information and safety
instructions provided by the manufacturer.
6. Operation
6.1 Changing between mains/battery
operation and infl ator/defl ator
compressed air/low-pressure blower
operation (Fig. 7)
To change over between mains-powered and
battery-powered operation, press the selector
switch (10):
•
DC/switch to the right:
The equipment will be supplied with power
from the rechargeable battery.
•
AC/switch to the left:
The equipment will be supplied with power
from the power cable.
To change over between compressed air and
low-pressure operation, press the selector switch
(12):
•
Switch to the left: Compressed air operation
•
Switch in the middle: OFF
•
Switch to the right: Low-pressure operation
6.2 Infl ator compressed air operation (Fig. 1a,
1b, 2, 7)
•
To inflate objects with compressed air, use
the compressed air hose (5).
•
Connect the adapter of the compressed air
hose to the object you wish to inflate.
•
Depending on what you are inflating, also
use the adapters (7, 8, 9) or other adapters
available from retail stores.
•
The pressure at the compressed air hose will
be displayed in the display (11).
•
The unit of the displayed pressure can be
selected with the button (15). The pressure
can be displayed in units of [bar], [PSI] or
[kPa]n.
•
The button (14) allows the desired pressure
to be reduced.
•
The button (16) allows the desired pressure
to be increased.
•
Switch on the equipment by moving the
selector switch (12) to the compressed air
operation position (see 6.1.).
•
The inflator will then pump until the preset
pressure on the display is reached, then it will
switch off.
•
Warning! Observe the information supplied
by the tire manufacturer and the vehicle
Anl_PRESSITO_USA_SPK7.indb 14
Anl_PRESSITO_USA_SPK7.indb 14
EN
manufacturer relating to the recommended
tire pressure.
•
Warning! This equipment is not calibrated!
For a calibrated measurement value, check
the actual tire pressure using a calibrated
meter after you have inflated the tires
yourself, e.g. at a petrol station.
•
Just before it is switched off, the pressure
which is shown in the display can be
0.73 - 2.9 psi (0,05 - 0,2 bar) higher than
the preselected pressure, because of
overpressure in the air hose.
•
Allow the inflator to cool down for about 5
minutes after every 5 minutes of operation in
order to prevent overheating.
6.3 Low-pressure blower operation
(Fig. 1a, 3, 4, 7)
6.3.1 Suctioning air (Fig. 1a, 3, 7)
•
To suction out objects with a large volume
until they are empty (e.g. deflating an air
mattress, etc.), connect the air hose (3) to the
extractor connection (13).
•
Connect the air hose to the object you wish
to deflate.
•
Switch on the equipment by moving the
selector switch (10) to the low-pressure
operation position (see 6.1.).
•
Switch off the equipment once the object has
been sufficiently deflated.
6.3.2 Infl ating (Fig. 1a, 4, 7)
Warning! When using the equipment to infl ate
objects, check the information and safety
instructions provided by the manufacturer.
•
To inflate objects with a large volume (e.g.
inflating an air mattress, etc.), connect the air
hose (3) to the inflating connection (4).
•
Connect the air hose to the object you wish
to inflate.
•
Switch on the equipment by moving the
selector switch (12) to the low-pressure
operation position (see 6.1.).
•
Switch off the equipment once the object has
been sufficiently inflated.
6.4 Charging the Li battery pack
The corresponding instructions can be found
in the original operating instructions for your
charger.
- 14 -
24.03.2020 11:14:21
24.03.2020 11:14:21