Leak Testing; Before Testing - Ooni Karu 16 Manual

Ocultar thumbs Ver también para Karu 16:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Leak Testing

General
Although the gas connections of the appliance are leak tested prior packing and shipment, a complete test
must be performed at the installation site.
Before each use, check all the gas connections for leak testing using the procedure listed below. If the smell
of gas is detected at any time, you should immediately stop using and check the entire system for leaks.

Before testing

Make sure all packing material has been removed from the appliance.
Make a solution of one part liquid detergent and one part water. You will need a spray bottle, brush or rag to
apply the solution to the fittings.
To test
1. Turn the burner valve OFF
2. Turn on the natural gas supply.
3. Apply the soap solution to all gas fittings. Soap bubbles would appear where a leak is present.
4. If a leak is present, immediately turn the gas supply OFF and tighten leaky fittings.
5. Turn the gas back ON and recheck.
6. Should the gas continue to leak from any of the fittings, turn the gas supply OFF and contact customer
service.