Step 6
Connect to gas canister
WARNING
• Please always keep the gas bottle in upright position.
• The size for 20 lbs LP gas cylinder is 12.2 inches in diameter and 17.9 inches tall
• If the appliance is not in use, the gas must be turned off at the supply cylinder.
• The cylinder used must include a collar to protect the cylinder valve.
• The minimum distance for the appliance and the 20lb gas tank is 40 inches apart.
QCC1 gas regulator
This gas fitting is clockwise. Make sure that the tank is completely switched off and screw the
regulator as far as possible into the gas tank valve.
Connecting the liquid propane gas cylinder
1. The cylinder valve should be in OFF position.
2. Make sure the burner valve is in OFF position.
3. Inspect the valve connections, port and regulator assembly. Remove debris and inspect the hose for damage.
4. When connecting the regulator assembly to the valve, use your hand to tighten the nut clockwise until it stops.
Use of a wrench could damage the quick coupling nut and result in a hazardous situation.
5. Open the cylinder valve fully by turning the valve counter-clockwise.
6. Before lighting the oven, use a soap and water solution to check all connections for leaks.
7. If a leak is found, turn the cylinder valve OFF, and do not use the oven until local liquid propane dealer can
make repairs.
Disconnecting the liquid propane gas cylinder
1. Turn the oven burner valve OFF and make sure the oven is cool.
2. Turn the liquid propane cylinder valve OFF by turning clockwise until it stops.
3. Detach the regulator assembly from the cylinder valve by turning the quick coupling nut counter-clockwise.
4. Place dust cap for cylinder valve outlet whenever the cylinder is not in use.
10

Leak Testing

General
Although the gas connections of the appliance are leak tested prior packing and shipment, a complete test
must be performed at the installation site.
Before each use, check all the gas connections for leak testing using the procedure listed below. If the smell
of gas is detected at any time, you should immediately stop using and check the entire system for leaks.

Before testing

Make sure all packing material has been removed from the appliance.
Make a solution of one part liquid detergent and one part water. You will need a spray bottle, brush or rag to
apply the solution to the fittings.
To test
1. Turn the burner valve OFF
2. Turn the liquid propane cylinder valve on counter-clockwise to open the valve.
3. Apply the soap solution to all gas fittings. Soap bubbles would appear where a leak is present.
4. If a leak is present, immediately turn the gas supply OFF and tighten leaky fittings.
5. Turn the gas back ON and recheck.
6. Should the gas continue to leak from any of the fittings, turn the gas supply OFF and contact customer
service.