Problems
1– The machine does not start
2– The propeller turns clockwise (on the three-phase model)
3– The product is not ground correctly
Causes
1– The differential switch is in the "0" position.
1– The plug switch is in the "0" position.
1– The start pushbutton does not work.
1– The electrical motor is faulty.
2– Motor wire inverted.
3– Plate and blade are not tightened correctly.
3– Scoring on the plate or blade is not perfectly adherent
(on the plate plane).
3– Mouth is not perfectly fastened.
Solutions
1– Put the switch in position "I".
1- Put the switch in position "I".
1– Contact servicing department.
1– Contact servicing department.
2– Ask technical assistance (dealer).
3– Correctly tighten the plate and blade.
3– Replace the faulty plate and blade pair.
3– Correctly fasten the mouth.