Mounting Installation Plate
Ensure that the wall is strong enough to withstand the weight
of the unit. Otherwise, it is necessary to reinforce the wall
with plates, beams or pillars.
Use the level gauge for horizontal mounting, and fix it with
5 suitable screws for (5)WM09/10/15J/JR and 7 suitable
screws for WM20/25J/JR.
In case the rear piping draws out, drill a hole 65mm in
diameter with a cone drill, slightly lower on the outside
wall (see figure).
(5)WM09/10/15J/JR
Mounting plate
fixing screw
WM20/25J/JR
Mounting plate
fixing screw
Recommended Mounting Plate Retention Spots
And Dimensions
(5)WM09/10/15J/JR
Recommended mounting plate
retention spots (5 spots in all)
166
54.5
153.8
51.9
263
Liquid pipe end
WM20/25J/JR
Recommended mounting plate
retention spots (7 spots in all)
190
Liquid pipe end
45
91
580
1 IM-WMJ-1207(2)_EN
Mounting plate
Mounting plate
Use tape measure as shown.
Position the end of a tape measure
at
184
Through
the wall
hole
Ø 65mm
55.5
181.7
Drain
800
hose
position
Gas pipe end
All dimensions are in mm
173
Through
the wall
hole
Ø 65mm
Drain hose
Gas pipe end
219
48
45
position
1065
All dimensions are in mm
8
Hole with cone drill
Inside
Wall embedded pipe
(Field supply)
Wall hole cover
(Field supply)
Mount The Unit Onto The Installation Plate
Hook the indoor unit onto the upper portion of the
installation plate (Engage the two hooks at the rear top of
the indoor unit with the upper edge of the installation plate).
Ensure that the hooks are properly seated on the
installation plate by moving it to the left and right.
How To Attach The Indoor Unit
Hook the claws of the bottom frame to the mounting plate.
How To Remove The Indoor Unit
Push up the marked area (at the lower part of the front grille)
to release the claws.
Bottom frame
Front grille
Hang indoor unit's hook here.
When stripping the
ends of interconnecting
wires in advance, bind
right ends of wires with
insulating tape.
Wire guide
Water Drainage Piping
The indoor drain pipe must be in a downward gradient for
smooth drainage. Avoid situations that are likely to cause
water to leak.
Water Drainage
Water
Water
leaking
leaking
Correct
Wrong
1-8
11/20/09, 4:32 PM
Outside
Caulking
Ø 65
Wall embedded pipe
(Field supply)
Mounting
plate
Clip
Mark (rear side)
Mounting plate
Interconnecting
wires
Water
Retention
End
dipped
Water
into
leaking
water
Drain
Wrong
Wrong