7.
Operation
i After switching on the MERCURE 200 the software
version appears on the displays of the control/dis-
play panel for a few seconds. The 0 values are then
shown on the left and right of the display.
7.1
Display
Fig. 36:
Display elements
Item Description
1
Displays the active (selected) balancing program and
balancing positions.
2
Indication of external weight balancing point; it lights-up
green when the balancing position is reached.
3
Split and Matching program display
- During the Split program, the LEDs flash alternately in
accordance with the weight position
- During the Matching program, both LEDs light simulta-
neously
4
Displays the unit of measurement for the rim width and
rim diameter,
lit = mm,
not lit = inch.
5
Displays the balancing program,
lights up when Pax program is selected.
6
Displays the Match program, lights up when Match
program is active.
7
Displays the direction of rotation to reach the balancing
position,
top = turn clockwise,
bottom = turn anti-clockwise.
8
Indication of internal weight balancing point; it lights-up
green when the balancing position is reached.
9
Internal weight display.
10
External weight display.
11
Display of active or selected operator:
Left LED: OPERATOR 1
Right LED: OPERATOR 2
Both LEDs: OPERATOR 3
12
LED lit: Rim distance data are displayed or can be en-
tered.
13
LED lit: Rim width data are displayed or can be entered.
14
LED lit: Rim diameter data are displayed or can be en-
tered.
Tab. 2:
Werther International S.p.A.
Operation | MERCURE 200 | 59
7.2
Control keys
Fig. 37:
Key
Designation
Description
<OPERATOR> R Change of operator,
R call-up of basic settings (in conjunc-
tion with menu key)
R Call-up of calibration (in conjunction
with menu key)
R Alteration of values
<+>
R Alteration of settings
<->
+ = "On",
– = "Off".
R Selection of balancing program
<mm/inch>
If LED is on it indicates the measure-
ment unit is in mm; vice-versa, it is in
inch.
R Call-up of balancing program,
<ALU>
selection with <-> or <+>,
R selection of vehicle type (1 second).
<RIM DIAM-
R Rim diameter display.
ETER>
<RIM
R Rim width display,
WIDTH>
R Inch/mm unit selection.
R Display of rim distance from
<RIM DIS-
TANCE>
MERCURE 200.
R Confirmation of rim data input.
R Confirmation of calibration data input
R Call-up of split program,
<SPLIT>
R end of split program,
R storage of calibration data,
<OPT>
Start "Unbalance minimization" pro-
gram.
LED lit: Program activated.
<MENU>
R Call-up of user-defined settings
R Call-up of basic settings.
R Call-up of calibration menu
<OK>
Deactivate "Attach adhesive weights"
program.
R Start: Start measurement
<START>
<STOP>
R Stop: End measurement;
R With unbalance display:
Display of exact value for measured
unbalance.
R exit from menu.
Tab. 3:
en
|
1 695 109 017