INSTRUCTION FOR USE
NOTE
For correct scrubbing/drying of floors at the sides of the walls, it is Suggested to go near the walls with the right
side of the machine (A and B, Figure 8) as shown in the figure.
CAUTION!
To avoid any damage to the floor surface, turn off the brushes/pad-holders when the machine stops in one
place.
TANK EMPTYING
An automatic float shut-off system (B, Figure 9) blocks the vacuum
system when the recovery water tank (C) is full. The vacuum system
deactivation is signaled by a sudden increase in the vacuum system
motor noise frequency, also the floor has not dried.
CAUTION!
If the vacuum system turns off accidentally
(for example, when the float is activated be-
cause of a sudden machine movement), to re-
sume the operation: press the power switch
(39 and 41) to turn off the power and vacuum
system, then open the cover (A, Figure 9) and
check that the float inside the grid (B) has
gone down to the water level. Then close the
cover (A) and press the power switch (39 and
41) turn on the main power and the vacuum
system.
When the recovery water tank (C, Figure 9) is full, empty it according to the following procedure.
Figure 8
Figure 8
C
14
ENGLISH
B
A
B
Figure 9
Figure 9
D