INSTRUCTION FOR USE
SCHEDULED MAINTENANCE TABLE
CAUTION!
The procedure marked with (1) must be performed when the machine is used after 9 hours for the first time. The
procedure marked with (2) must be done by Service Center that is qualified by our company.
Procedure
Squeegee cleaning
Brush/Pad-holder cleaning
Tank cleaning
Tank sealing strip inspection
Float ball filter cleaning
Squeegee blade check and replacement
Cleaning water filter cleaning
Solution filter cleaning
Screw and nut tightness inspection
Brush/Pad-holder carbon brush check or replacement
Suction motor carbon brush check or replacement
BRUSH/PAD CLEANING
CAUTION!
It is advisable to use protective gloves when cleaning the brush/pad because there may be sharp debris.
1.
Remove the brush/pad from the machine, as shown in the Use chapter.
2.
Clean and wash the brush/pad with water and detergent.
3.
Check that the brushes/pads are in working condition and not excessively worn; if necessary replace them.
SOLUTION FILTER CLEANING
1.
Pushing the machine on a level floor.
2.
Ensure that the machine is off.
3.
Emptying the solution tank (Advice).
4.
Remove the cover (D, Figure 11), then remove the filter strainer (C).
Clean and install them on the support (A).
NOTE
The filter strainer (C, Figure 11) must be cor-
rectly positioned on the housing (E) of the sup-
port (A).
Daily, after each use
A
B
C
D
16
Weekly
semiannually
(1)
E
C
Figure 11
Figure 11
ENGLISH
Yearly
(2)
(2)