Tank Emptying; After Using The Machine - Viper AS1050R Guia De Inicio Rapido

Ocultar thumbs Ver también para AS1050R:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 88
QUICK START GUIDE
 

TANK EMPTYING

Recovery water tank emptying
When the Multifunction display (47, Figure 3) show ERROR24 and the recovery tank full indicator (48, Figure 3) is turned on. It
indicates the recovery tank (C, Figure 15) is full, the vacuum motor cannot longer dry the floor. Empty the recovery tank as following
steps:
1.
Stop the machine.
2.
Lift the brush/pad-holder deck and the squeegee by pressing the one-button start (51, Figure 3).
3.
Drive the machine to the appointed disposal area.
4.
Empty the recovery water tank with the hose (D, Figure 15). Then, rinse the tank (C, Figure 15) with clean water.
CAUTION!
When draining the wastewater, the hold the drain hose
high, and fold over the top section to avoid spilling onto
the operator.
Solution/clean water tank emptying
1.
Empty the solution tank with the outlet cover (A, Figure 15). After working,
rinse the tank with clean water.

AFTER USING THE MACHINE

After working, before leaving the machine:
1.
Remove the brushes/pad-holders by pressing the release left button (56, Figure
3) and clean them.
2.
Empty the tanks (B and C, Figure 15) as shown in the previous paragraph.
3.
Perform the daily maintenance procedures (see the Maintenance chapter).
4.
Store the machine in a clean and dry place, with the brushes/ pad-holders and the
squeegee lifted or removed.
5.
Use the recovery tank lid support to keep the lid open. This will help prevent
odors from building up inside.
MACHINE STORAGE DURING LONG INACTIVITY
If the machine is not going to be used for more than 30 days, proceed as follows:
1.
Perform the procedures shown in After Using the machine paragraph.
2.
Disconnect the battery connector.
FIRST PERIOD OF USE
After the first 8 hours, check the machine fastening and connecting parts for proper tightening and check the visible parts for wear and
leakage.
MAINTENANCE
WARNING!
Maintenance procedures must be performed after the machine is turned off and the battery charger cable is
disconnected. In addition, carefully read the safety chapters in these instructions.
All scheduled or extraordinary maintenance procedures must be performed by qualified personnel or an authorized Service Center. This
manual only describes the general and common maintenance procedures.
For other maintenance procedures that are not in below maintenance schedule table, please contact our Technical Support Department.
13 