ADDITIONAL FUNCTIONS
7

Commissioning

7.1

Alignment

8
causes: Sensor is contaminated, sensor is out of alignment, cable is damaged. In the
good state: HIGH (1), if excessively contaminated or in the event of cable interruption
LOW (0). The yellow LED indicator flashes in this case.
Test input
Test input: The sensors WTB26 feature a test input ("TI" or "Test" on the connection
diagram
[see table
2]), which can be used to switch the sender off and, therefore,
check that the sensor is functioning correctly: If female cable connectors with LED
indicators are used, you have to ensure that the TI is assigned accordingly.
If an object is detected, activate the test input (see the connection diagram
table
2]).
The send LED is shut down or no object being detected is simulated. Refer to
to check the function. If the switching output fails to behave in accordance with the
graphic, check the application conditions,
Table 5: Test
WTB26P: Align the sensor with the object. Select the position so that the red emitted
light beam hits the center of the object. You must ensure that the optical opening (front
screen) of the sensor is completely clear [see table].
Align the sensor with the object. Select the position so that the infrared light (not
visible) hits the center of the object. The correct alignment can only be detected via the
LEDs. See
table
and
table
the sensor is completely clear.
see "Troubleshooting", page
Test → M
+ (L+)
Test
– (M)
+ (L+)
Test
– (M)
4. You must ensure that the optical opening (front screen) of
[see
table 5
14.
Test → L+
+ (L+)
Test
– (M)
+ (L+)
Test
– (M)
8020354.19RH / 15.01.2021 | SICK
Subject to change without notice