Section 3
Installation
Electronic controller must be connected to a Ground Fault Protected Circuit (GFCI) receptacle. Ensure green ground wire ring terminal is securely
fastened to ground stud on UV chamber.
3.1 Installing UV System
Prerequisites:
•
Determine appropriate indoor location of the controller and chamber. Refer to
•
Ensure adequate clearance above chamber to allow for removal of the lamp and sleeve.
•
Make sure to turn off the main water supply.
•
Mount the system to the wall with appropriate lag bolts through the two mounting holes located on the metal bracket.
The supplied lag bolts are suitable for attachment to wood. (Attachments to other materials will require purchasing of
alternative hardware).
•
Make all necessary plumbing connections. Refer to
Procedure:
1
• Screw chamber clamp(s) to
the wall (#10 screws
recommended.)
Optional - Powers solenoid valves, remote alarms and auto-dialers.
Powers and controls the UV lamp and other devices. Provides human interface, displaying
information and allowing control inputs (such as muting the audible alarm).
Provides power to the controller. For safety reasons the outlet must be protected by a Ground Fault
Circuit Interrupter (GFCI). NOTE: to protect the controller, a UL1449 certified (or equivalent) transient
voltage surge suppressor is required.
Ø
L
20.5" (52cm)
4" (10cm)
30" (76cm)
4" (10cm)
44.25" (112.4cm)
4" (10cm)
C A U T I O N
2
• Insert chamber and tighten
clamp(s).
• Make all necessary plumbing
connections. Refer to
Section
2.1.
Function
A (maximum)
B
72" (183cm)
8.5" (22cm)
72" (183cm)
8.5" (22cm)
72" (183cm)
8.5" (22cm)
Figure
3.
3
• Mount controller mounting
bracket to wall using four #8
screws (not provided).
C
D (maximum)
6" (15cm)
6" (15cm)
6" (15cm)
Figure
3.
4
• Slide controller onto mounting
bracket.
Installation
54" (137cm)
54" (137cm)
54" (137cm)
8