Specifications
Section 7
Specifications
Operating Parameters
Maximum operating pressure
Minimum operating pressure
Maximum ambient air temperature
Minimum ambient air temperature
Maximum humidity
Maximum hardness
Maximum iron
Minimum UVT
Installation
Flow Restrictor
NSF Certification
Rated service life of lamp
UV System Certification
Model
Maximum rated flow at dose of 16 mJ/cm
95% UVT
Maximum rated flow at dose of 30 mJ/cm
95% UVT
Maximum rated flow at dose of 40 mJ/cm
95% UVT
Rated flow for NSF Std 55, Class B (-V versions
only)
Voltage
Frequency
Max. current
Max. power consumption
Lamp power
UV Chamber Material
Inlet/Outlet
17
General (All Models)
125 PSI (862 kPa)
4 PSI (27.5 kPa)
122 ºF (50 ºC)
32 ºF (0 ºC)
100%
120 ppm (7 grains per gallon)
0.3 ppm
75%
Vertical or horizontal*
-
-
1 year
D4/D4+
D4-V/D4-V+
2
@
23 gpm (87 lpm) (5.22 m
2
@
12 gpm (45 lpm) (2.73 m
2
@
9 gpm (34 lpm) (2.04 m
8.9 gpm (33.7 lpm) (2.02 m
100-240V AC
50-60 Hz
0.5 Amp
50 Watts
40 Watts
304 SST
3/4" NPT
NSF Standard 55 Class B Models (-V)
125 PSI (862 kPa)
4 PSI (27.5 kPa)
122 ºF (50 ºC)
32 ºF (0 ºC)
100%
120 ppm (7 grains per gallon)
0.3 ppm
75%
Vertical or horizontal*
Yes
NSF Standard 55 Class B
1 year
E4/E4+
E4-V/E4-V+
3
/hr)
42 gpm (160 lpm) (9.54 m
3
/hr)
22 gpm (83 lpm) (5 m
3
/hr)
16 gpm (60 lpm) (3.63 m
3
/hr)
15.8 gpm (59.8 lpm) (3.6 m
100-240V AC
50-60 Hz
0.85 Amp
83 Watts
70 Watts
304 SST
1" NPT
F4/F4+
F4-V/F4-V+
3
/hr)
45 gpm (170 lpm) (10.22 m
3
/hr)
36 gpm (136 lpm) (8.18 m
3
/hr)
27 gpm (102 lpm) (6.13 m
3
/hr)
26.1 gpm (98.8 lpm) (5.93 m
100-240V AC
50-60 Hz
1.2 Amp
130 Watts
110 Watts
304 SST
1" NPT
3
/hr)
3
/hr)
3
/hr)
3
/hr)