Section 5
Maintenance
Always disconnect power before performing any work on the disinfection system.
Always shut-off water flow and release water pressure before servicing.
Regularly inspect your disinfection system to ensure that the power indicators are on and no alarms are present.
Replace the UV lamp annually (or biennially if seasonal home use) to ensure maximum disinfection.
Always drain the chamber when closing a seasonal home or leaving the unit in an area subject to freezing temperatures.
5.1 Replacing UV Lamp
Do not use water during replacement of UV lamp.
Lamp replacement is a quick and simple procedure requiring no special tools. The UV lamp must be replaced after 9000
hours of continuous operation (approximately one year) in order to ensure adequate disinfection.
Procedure:
1
• Close all faucets and water
supply.
• Press the pressure release
button to relieve the pressure
from the cartridges.
1
5
• Remove lamp/sleeve
assembly along with sleeve
bolt from chamber.
2
• Disconnect main power
source and allow the unit to
cool for 10 minutes.
6
1
1
2
2
2
• Unscrew the UV lamp by
holding the sleeve bolt.
WA R N I N G
N O T I C E
3
1
10 mins
• Remove the safety cap by
squeezing the tabs.
Note: Ensure the lamp plug
wires remain connected.
7
1
2
UV
3
Hg
• Remove the sleeve bolt and
remove 2 O-rings from the
sleeve.
• Install 2 new O-rings onto
sleeve on either side of
sleeve bolt as pictured.
4
2
• Remove the lamp plug.
Note: Ensure the strain relief
wires remain connected.
8
2
1
2
1
3
• Install and secure the new
lamp into sleeve.
Note: Over tightening will
break the sleeve.
Maintenance
2
UV
1
Hg
12