Installation
9
1
• Wet O-ring with water then
place over bottom end of
sleeve.
• Reconnect the sleeve bolt
and install screw.
13
13
• Install lamp harness onto
chamber.
Note: Ensure lamp harness
ground is inserted into
chamber ground terminal
• Lock wire form into position.
Note: After installing the UV lamp or sleeve perform the disinfection procedure, refer to
3.2 Disinfection Procedure
UV disinfection is a physical disinfection process and does not add any potentially harmful chemicals to the water. As UV
does not provide a disinfection residual, it is imperative that the entire distribution system located after the UV be chemically
disinfected to ensure that the plumbing system is free from any bacteriological contaminants. The disinfection process must
be performed immediately after the UV unit is installed and repeated thereafter whenever the UV is shut down for service,
without power, or inoperative for any reason. The procedure for sanitizing the plumbing system is readily accomplished as
follows:
9
10
10
2
1
2
3
• Install and rotate the lamp
into the sleeve assembly.
Ensure to rotate the lamp
completely.
Note: Do not touch glass with
bare hands.
14
14
• Connect controller to power
outlet.
• Allow water flow to one faucet
or other water outlet, then
close the outlet and inspect
for leaks.
Note: Outlet must be
protected by a Ground Fault
Circuit Interrupter (GFCI).
11
11
UV
4¹⁄16"
(10.4cm)
Hg
• Install the controller unit to
the wall. Ensure that the
controller is installed higher
than the chamber and away
from all water sources.
12
12
3
2
1
• Connect UV sensor into blue
jack (For PRO and Plus
models only).
• Connect Flow meter sensor
into green jack (For PRO10,
20, 30 only).
• Connect CoolTouch™ fan
into either receptacle.