Maintenance
Procedure:
1
1
• Remove the sleeve bolt from
top of the sleeve assembly.
5
• Remove the sleeve.
9
• Reinstall the sleeve with
arrow pointing up.
Note: DO NOT rotate sleeve
and touch glass with bare
hands.
13
2
2
2
• Remove screw from the
sleeve bolt.
• Remove the sleeve bolt at the
bottom of the sleeve
assembly.
6
• Remove O-ring from top of
the sleeve.
• Remove O-ring from bottom
of the chamber (it may fall
during sleeve removal
process).
10
10
• Reinstall the new lubricated
O-rings over the top end of
the sleeve.
3
3
1
• Insert the sleeve removal tool
into the bottom of the sleeve.
7
• Clean the sleeve with a cloth
soaked in CLR, vinegar or
some other mild acid and
then rinse with water.
Note: If sleeve cannot be
cleaned completely or it is
scratched or cracked, then
replace the sleeve.
11
11
1
• Connect the sleeve bolt to the
top of the sleeve assembly.
4
• Pry sleeve upward until it
come loose.
• Place bucket under UV
chamber, water will escape.
8
2
Mild
Acid
• Connect the sleeve bolt at the
bottom of the sleeve
assembly.
12
12
2
1
• Remove the sleeve bolt at the
bottom of the sleeve
assembly.
1
3
2