Maintenance
Section 4
Maintenance
•
Always disconnect power before performing any work on the disinfection system.
•
Always shut-off water flow and release water pressure before servicing.
•
Regularly inspect your disinfection system to ensure that the power indicators are on and no alarms are present.
•
Replace the UV lamp annually (or biennially if seasonal home use) to ensure maximum disinfection.
•
Always drain the chamber when closing a seasonal home or leaving the unit in an area subject to freezing temperatures.
4.1 Replacing UV Lamp
Do not use water during replacement of UV lamp.
UV lamp replacement is a quick and simple procedure requiring no special tools. The UV lamp must be replaced after 9000
hours of continuous operation (approximately one year) in order to ensure adequate disinfection.
Procedure:
1
2
1
• Close all faucets and water
supply.
• Press the pressure button to
release the pressure from the
cartridges.
5
• Remove the lamp connector.
11
WA R N I N G
N O T I C E
2
1
10 mins
• Disconnect main power
source and allow the unit to
power down for 10 minutes.
6
1
2
• Rotate and remove the UV
lamp from the sleeve.
3
1
• Drain the water from the UV
system.
• Close the water inlet after the
water is drained.
7
UV
2
1
Hg
• Install and rotate the lamp
into the sleeve assembly.
Ensure to rotate the lamp
completely.
Note: Do not touch glass
with bare hands.
4
2
• Pinch wire form to release the
lamp connector.
8
UV
Hg
• Reinstall the lamp connector.