Procedure:
1
2
• Disconnect the controller then
disconnect the UV sensor
from blue jack.
• Reconnect the controller with
out UV sensor.
5
1
2
x2
• Remove cartridge(s) and
pour 2 cups of household
bleach solution into the filter
housing(s).
Note: DO NOT use Hydrogen
Peroxide.
9
• With all faucets closed,
remove filter housing(s)
using sump wrench.
2
1
2
2
2
2
• Shut off the water supply.
• Open an upstream faucet to
release line pressure
6
• Connect only the filter
housing(s) to the unit.
10
10
1
2
• Reinstall the cartridge(s) into
filter housing(s) and connect
to the unit.
• Flush all water outlets until
bleach can no longer be
smelled (at least 5 minutes).
3
• Press the pressure button to
release the pressure from the
cartridges.
7
• Open each faucets and turn
on water supply.
• Allow water to fill the
chamber.
11
11
• Press the pressure button to
purge air and to complete the
disinfection procedure.
Installation
4
• Remove filter housing(s)
using sump wrench.
8
30 mins
• Turn on the cold water supply
followed by hot water (if
available) until you smell the
bleach.
• Close all faucets and allow
bleach to settle in the water
lines for 30 minutes.
12
12
2
• Disconnect the controller then
connect the UV sensor from
blue jack.
• Reconnect the controller.
10