2.
Diagnostic Test
Diagnostic Test can be used to check functionality of various machine parts.
Press Start to move through the check points.
Number of times the
Start button is
pressed
0
-
1
2
3
4
5
6
7
8
9
NOTE
• Make sure the drum is empty when diagnostic test is being performed. Do not use
Check point
Enter SVC Mode
Press 2nd button
Check the version and code for machine.
• Electric Coin type : P0:OE
• Electric Card type : P0:CE
• Electric OPL type : P0:PE
• Gas Coin type : P0:Og
• Gas Card type : P0:Cg
• Gas OPL type : P0:Pg
PDA Check
Motor runs
• Elctric type : Heater runs
(Motor + Heater 1 (2700W))
• Gas Type : Motor runs
• Elctric type : Heater runs
(Motor + Heater 1+Heater 2 (5400W))
• Gas Type : Gas valve runs (Motor +Valve)
LED&Button Check
Press the whole course buttons.
Test Ends
Door switch (Motor&Heater Off, Buzzer
beeps seven times)
Test goes back at step 3. (Motor on &
Heater Off )
PROGRAmmING mODE
Display
Displays
, P0:XX, gU:XX, gd:XX
and gF:XX alternately (Version)
Measured moisture value (70~239)
Current temperature (5~70)
(Display shows the temperature inside the
drum in Celsius)
Current temperature (5~70)
(Display shows the temperature inside the
drum in Celsius)
Displays
, P0:XX, gU:XX, gd:XX
and gF:XX alternately (Version)
dE (The door is open. Please close the door
completely)
Measured moisture value (70~239)
49
EN
.