Window Mask - Interlogix DD300-P Serie Hoja De Instalación

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 6
Select the required function of the LED at jumper J2.
DUAL: Detector Alarm. The LED lights when the detector
is in alarm. Relay follows LED.
ULTRASONIC: Ultrasonic Alarm. The LED lights when the
ultrasonic channel is in alarm. Relay is always in alarm.
PIR: PIR alarm. The LED lights when the signal in the PIR
channel exceeds the alarm level. Relay is always in alarm.
Use "ULTRASONIC" and "PIR" when required to locate the
coverage patterns of the individual technologies.
Range adjustment
See Figure 2a.
Program the range at jumper J1.
12 m: maximum range up to 12 m.
8 m: medium range up to 8 m.
5 m: minimum range up to 5 m.
Always select the lowest range setting possible for the
dimensions of the protected area.
1.
Select PIR channel on jumper J2. Verify PIR coverage and
adjust if required.
2.
Select ULTRASONIC channel on jumper J2. Verify
ULTRASONIC coverage and adjust if required.
3.
Select DUAL processing on jumper J2 and verify unit
detection.
LED jumper and remote control of LED
(DD325-P/DD326-P only)
See Figures 2a and 2b.
Move jumper J3 to position OFF/REMOTE. The LED is now
disabled. It may be enabled by moving the jumper J3 to the ON
position or remotely by applying a 0 V potential to terminal 8.
Alarm memory (DD335-P/DD336-P only)
See Figure 2c.
Connect "CV" to terminal 9 by arming the system. If an alarm
has occurred during the armed period, the detector or
detectors which gave the alarm are indicated by a flashing LED
when the system is disarmed and walk test is off. Re-applying
the "CV" (re-arming the system) will reset LED indication and
memory.
Remote enable/disable of walk test LED
See Figure 3.
To walk test the detector, disarm the system and switch "CV"
to terminal 10 (Walk test).
Notes
Enabling the walk test will not clear alarm memory.
To enable the walk test LED without a remote "CV" input,
connect a link between terminal 2 and 10.
P/N 143541999-2 • REV C • ISS 29NOV12
Caution: Ultrasonic disable.
additional feature that whenever the system is disarmed with
the walk test off, the ultrasonic transmitter will be switched off.
The detector will then operate as a PIR only. In all other
configurations the unit operates in dual technology mode.

Window mask

See Figure 4.
In the presence of objects close to (within 1.5 m) and directly
under the detector, fit the mask to the inside of the window as
shown. This disables the part of the curtains looking at the
object, whose closeness might otherwise destabilize the
detector.
Specifications
Supply voltage
9 to 15 V
Peak-to-peak ripple V, p-p
2 V max. (at 12 V )
Current consumption:
Normal operation
DD325-P, DD335-P: 18 mA
DD326-P, DD336-P: 22 mA
Alarm
22 mA max.
Mounting height
1.8 to 3.0 m
Target speed range
0.2 to 4.0 m/s
Number of curtains
7
Ultrasonic frequency
26.3 kHz
Sound pressure
100 dB max. at 30 cm
Alarm output
100 mA at 28 V
Tamper output
100 mA at 28 V
Alarm time
2.5 s min.
Latch
DD325-P, DD335-P: —
DD326-P, DD336-P: +12 V to terminal 9
Walk test
DD325-P, DD335-P: 0 V to terminal 8
DD326-P, DD336-P: +12 V to terminal 12
Temperature limit
DD325-P, DD335-P: −10 to +55°C
DD326-P, DD336-P: −10 to +50°C
Relative humidity
30 to 95%
Size
123 x 72 x 57 mm
Weight
150 g
Housing complies (with
IP30 IK02
sealed cable entry)
Certification and compliance
Manufacturer
UTC Fire & Security Americas Corporation, Inc.
1275 Red Fox Rd., Arden Hills, MN 55112-6943, USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Certification
1999/5/EC (R&TTE directive): Hereby, UTC Fire &
Security declares that this device is in compliance with
the essential requirements and other relevant
provisions of Directive 1999/5/EC.
DD335-P/DD336-P has the
(12 V nom.)
3 / 12
Tabla de contenido
loading

Este manual también es adecuado para:

Dd325-pDd335-pDd326-pDd336-p

Tabla de contenido