Wiring Connection; Gas Leak Test; Others; Setting Of Remote Control Selector Switch - Carrier 38VYX025-R Manual De Instalación

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 21
Packed valve handling precautions
• Open the valve stem all the way out, but do not try to open it beyond
the stopper.
• Securely tighten the valve stem cap with torque in the following table:
Gas side
30 to 42 N·m
(∅9.52 mm)
(3.0 to 4.2 kgf·m)
Liquid side
16 to 18 N·m
(∅6.35 mm)
(1.6 to 1.8 kgf·m)
9 to 10 N·m
Service port
(0.9 to 1.0 kgf·m)

Wiring Connection

1. Remove the valve cover from the outdoor unit.
2. Connect the connecting cable to the terminals as identified with their
respective matched numbers on the terminal block of indoor and
outdoor unit.
3. When connecting the connecting cable to the outdoor unit terminals,
make a loop as shown in the installation diagram of indoor and
outdoor unit to prevent water coming in the outdoor unit.
4. Insulate the unused cords (conductors) from any water coming in the
outdoor unit. Proceed them so that they do not touch any electrical or
metal parts.
Stripping length of the connecting cable
Terminal block
1
2
3
Connecting cable

Gas Leak Test

Electric parts cover
Check places for
the outdoor unit.
• Check the flare nut connections for the gas leak with a gas leak
detector or soap water.
The hexagon wrench
is required.
L
N
Earth line

OTHERS

Check places for
the indoor unit.
Valve cover
GB - 4
3
L
N
10
30
Connecting cable
Model
38VYX025-R
Power source
50/60 Hz, 220 – 240 V Single phase
Maximum running current
Plug socket & fuse rating
Power cord
H07RN-F or 245 IEC66 (1.5 mm
CAUTION
• Wrong wiring connection may cause some electrical parts burn out.
• Be sure to comply with local cords on running the wire from indoor
unit to outdoor unit (size of wire and wiring method, etc.).
• Every wire must be connected firmly.
• This installation fuse (25A) must be used for the power supply line
of this air conditioner.
• If incorrect or incomplete wiring is carried out, it will cause an
ignition or smoke.
• Prepare the power supply for exclusive use with the air conditioner.
• This product can be connected to the mains.
Connection to fixed wiring: A switch which disconnects all poles
and has a contact separation of at least 3 mm must be
incorporated in the fixed wiring.
NOTE
: Connecting cable
• Wire type : More than H07RN-F or 245 IEC66
Setting of Remote Control
Selector Switch
When two indoor units are installed in the separated rooms, it
is not necessary to change the selector switches.
Remote control selector switch
• When two indoor units are installed in the same room or
adjacent two rooms, if operating a unit, two units may receive
the remote control signal simultaneously and operate. In this
case, the operation can be preserved by setting either one
indoor unit or remote control to B setting. (Both are set to A
setting in factory shipment.)
• The remote control signal is not received when the settings of
indoor unit and remote control are different.
• There is no relation between A setting/B setting and A room/B
room when connecting the piping and cables.
10
40
Earth line
38VYX035-R
8A
11A
25A
2
or more)
Tabla de contenido
loading

Este manual también es adecuado para:

38vyx035-r

Tabla de contenido