3.
Adjustments
WARNING
Risk of injury
» Only make adjustments when the
machine is switched off.
3.1
Changing the direction of rotation
Clockwise
» See Figure 1
Counterclockwise
» See Figure 2
3.2
Changing gears
1st gear (Lo) = Low RPM range
» See Figure 3
2nd gear (Hi) = High RPM range
» See Figure 4
3.3
Adjusting torque
Screwing
» See Figure 5
Drilling
» See Figure 6
4.
Operation
WARNING
Risk of injury from unintentional
actuation of the On/Off switch
» Remove the battery before performing
any work on the machine.
4.1
Switching on/off
RPMs are infinitely adjustable depending
on the pressure on the On/Off switch.
Switching on
» See Figure 7
Switching off
» See Figure 8
14
BA_TruTool_DD1010_2014-12-16.indb 14
4.2
Changing the battery
The battery can be used immediately
upon delivery and can be charged at any
time.
Removing the battery
» See Figure 9
Inserting the battery
» See Figure 10
4.3
Battery capacity display
When the On/Off switch is actuated, the
battery capacity display displays the bat-
tery charge level.
» See Figure 11
4.4
Charging the battery
See operator's manual for the recharger.
4.5
Changing tools
» See Figure 12
5.
Maintenance and service
WARNING
Risk of electric shock
» Remove the battery before perform-
ing any repair or service work on the
machine.
» Have all maintenance and repair work
that requires the motor housing to be
opened performed by an authorized
service center.
Service and repairs
Have service and repairs performed only
by the manufacturer or a service center.
The nearest service center can be found
at:
www.trumpf-powertools.com
Only use original TRUMPF replacement
parts and accessories, which can be
ordered from your specialized TRUMPF
dealer.
Observe the following information:
- Keep the ventilation openings on the
power tool free and clean so that the
tool is adequately cooled.
22.05.2015 09:48:03